12. Appliance description CEW-2-200
CEW-2-200 DHW cylinder with internal indirect coil
Steel cylinder with corrosion protection provided by special enamelled
coating on the inner wall of the cylinder, compliant to DIN 4753. Additional
corrosion protection provided by sacrificial magnesium anode.
Suitable for systems to DIN 1988, EN 12828 and DIN 4753.
Dimensions and design are tailored to the Wolf heat pump range, enabling
variable combination.
The casing is designed for high load-bearing capacity, to allow the indoor
module of a BWL-1S split air/water heat pump to be mounted on the
CEW-2-200.
The DHW cylinder is equipped with a highly efficient bare-tube heat
exchanger with indirect dual coil for convenient DHW heating.
The PU rigid foam insulation ensures minimum radiation and standby heat
losses.
Standard delivery
Packaged in box, fully encased, ready for
connection, incl. boiler drain & fill valve,
adjustable feet, installed sensor well;
installation instructions included.
The CEW-2-200 can be installed in combination with the BWL-1S-07/10/14
or BWL-1SB-07/10/14 as a stacked heating centre.
Split heating centre with CEW-2-200
Height, indoor module
Height, CEW-2-200
Overall height
Overall height with 25 l expansion vessel (ADG)
(accessories - on back of indoor unit)
Width
CEW-2-200
170
85
A mm
B mm
C mm
D mm
E mm
170
85
650
790
1290
2080
2160
650