Specification

DHW cylinder
Buffer cylinder
Max. operating pressure
Max. operating temperature
Cylinder capacity
Continuous cylinder output
t
80/60 °C  t
10/45 °C
v
DHW
Output factor (heating)
Output factor (heating)
Heat-up time 10 kW  10-
50 °C
Draw-off rate, DHW at 40 °C
(T
= 55 °C, 15 l/min)
cyl
Cold water connection
Return, heating / solar
Cylinder sensor, heating / solar C mm
DHW circulation
Flow, heating / solar
DHW connection
Electric booster heater (opt.)
Thermometer connection
Overall height
Diameter incl. insulation
Casing width / depth
Service flange
Height when tilted
Primary heating water
Secondary DHW
Internal flange diameter
Cold water connection
Return, heating / solar
DHW circulation
Flow, heating / solar
DHW connection
Protective anode (insulated)
Electric booster heater
Cylinder sensor
Thermometer
Indirect coil surface area,
heating / solar
Indirect coil content,
heating / solar
Weight
26
20. Specification CPM-1-70/7(8), CEW-1-200
Type
Type
CPM-1-70/7
bar
°C
l
kW - l/h
NL60
NL50
min
l
A mm
B mm
D mm
E mm
F mm
G mm
H mm
I mm
J mm
mm
L mm
mm
bar/°C
bar/°C
mm
G
G
G
G
G
G
G
G
G
l
kg
CPM-1-70
CPM-1-70/8
3
95
70
-
-
-
-
-
225/-
225/-
-
352/-
-
-
-
740
600
600 x 650
-
925
3/95
-
-
½" fem.
1 ½" male / -
-
1 ½" male / -
-
-
-
½" fem.
-
-
-
61
CEW-1-200
CEW-1-200
180
20/490
2.9
1.4
191
222/-
590/-
697
797/-
1194
1270
600
600 x 650
324
1395
3/95
10/95
DN 110
1" male
1 ½" male / -
¾" male
1 ½" male / -
1" male
1 ¼" fem.
1 ½" fem.
½" fem.
2.3/-
17/-
62
147
3064300_201703
10
95
59
90
-
-
-