Control Commands - Panasonic PT-DZ6710U Service Manual

Dlp based projector
Hide thumbs Also See for PT-DZ6710U:
Table of Contents

Advertisement

Error Response
Example 1: Query Power "QPW"
1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
2. Receives a response.
Response = "NTCONTROL 0" + (CR)
3. Transmits the command.
Transmission data = "00QPW" + (CR)
4. Receives a response.
Reception data = "00000" + (CR)
5. Disconnects the connection with the projector.
Example 2: Query FILTER INFORMATION - RUNTIME "QFI:0"
1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
2. Receives a response.
Response = "NTCONTROL 0" + (CR)
3. Transmits the command.
Transmission data = "00QFI:0" + (CR)
4. Receives a response.
Reception data = "00 (SP) (SP) 142" + (CR)
5. Disconnects the connection with the projector.
5.3.

Control commands

PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
Error Message
"ERR1"
Command format error
"ERR2"
Out of parameter
"ERR3"
Busy or unavailable time
"ERR4"
Timeout or unavailable time
"ERR5"
Data length error
"ERRA"
Invalid password
4 bytes
19
End character
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
1 byte

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents