Bit
Name
bit15
Warning of optical module
low temperature
bit14
Warning of optical module
high temperature
bit13
Warning of intake air high
temperature
bit12
Warning of exhaust air or
lamp surroundings high
temperature
bit11
For test
bit10
For extension
bit09
ACF time warning
bit08
Filter rotation error
bit07
LAMP2 time warning
bit06
LAMP1 time warning
bit05
Filter blocked error
bit04
For extension
bit03
Airflow sensor
disconnected
bit02
Color wheel rotation error
bit01
Cover open error
bit00
For extension
Parameters 2 (*6, *7, *8, *9)
For extension, the value is undefined.
Description
The ambient temperature in the place of use may be 0°C or lower.
If the temperature inside this projector does not rise within 5 minutes
after the turning on the lamp, the shutdown occurs.
The temperature inside this projector has become high. If the
temperature rises any further, the shutdown occurs.
- The ventilation holes may be closed.
- The ambient temperature in the place of use may be too high.
- The air filter may accumulate dust.
The value is undefined.
The value is undefined.
The ACF runtime exceeds specified cumulative usage time, and
becomes a period when the air filter is replaced.
It failed in the air filter rewinding in ACF.
It becomes a period when the lamp unit is replaced. Prepare a new
lamp unit. The shutdown will occur within 200 hours.
The air filter in ACF has no quantity, or it may accumulate dust.
The value is undefined.
The airflow sensor has breaking of wire, or connector RL11 is
disconnected.
The color wheel and/or color wheel drive circuit is abnormal. It is a
breakdown when not recovering even if the power is turned on again.
Does the lamp unit cover open?
The value is undefined.
80/80
Condition of
Clear Bit
- Becomes
higher than
the warning
release
temperature
during
power-on.
- Power ON
- Becomes
lower than
the warning
release
temperature
during
power-on.
- Power ON
MAIN
POWER ON
Filter reset
Filter reset
or Power ON
LAMP2 reset
LAMP1 reset
Filter reset
MAIN
POWER ON
Power ON
Close the
lamp unit
cover and
turn on
MAIN
POWER.