Steps During Initial Operation - Baier PROMETHEUS Series Instruction Manual

24v motor control device for flush box mounting
Table of Contents

Advertisement

Initial operation

6.2 Steps during initial operation

Moving wing
Danger of injury by squashing, shearing or collision, caused
by moving wing.
 Wing moves independently during initial operation.
 Keep danger area clear during initial operation.
 Prepare eletrical connections
 Refer to chapter 5.4
 Set configuration
 Refer to chapter 6.1
 Switch power supply on
 Control device in delivery status or after power cut:
Red LED blinks continuously twice with a short break of 1.5 sec
 Press RESET for 2 seconds
 Red LED blinks continuosly
 Check driving direction of motor
When pressing OPEN, wing has to open and when pressing CLOSE, wing has
to close
 When driving direction is wrong:
Swap motor cables (clamp 4 and 5), check driving direction again
 Press RESET again for 2 seconds
 Red LED lights up permanently,
Green LED lights up, when motor is active
 Drive performs a few runs.
 LEDs go out
 Red LED starts blinking continuosly
 In this state (about 30 seconds) additional complete cycles may be performed.
These cycles have to be triggered by user and are optional.
 After 30 seconds without any function, the LED goes out
 Check desired function
 In case of malfunction, check electrical connections and configuration
 Electrical connection, refer to chapter 5.4
 Configuration, refer to chapter 6.1
 Repeat initial operation, if necessary
 Initial operation is completed, when function is correct
24V motor control device for flush box mounting - Version 1.1
w w w . b a i e r - g m b h . d e
W A R N I N G
6
Prepare control device
Reset control device
...
...
...
...
Check function