Configuration Switch - Baier PROMETHEUS Series Instruction Manual

24v motor control device for flush box mounting
Table of Contents

Advertisement

6
Initial operation
14/22
Instruction manual
w w w . b a i e r - g m b h . d e

6.1.2 Configuration switch

Switch
OFF
ON
1
2
3
4
Table 1 – DIP-switch
1. Semiautomatic function /Deadman's control
When the semiautomatic function is active, the drive is active as long as no
obstruction is detected or the end position is not reached, even if the control
input is not active any more.
When the deadman's control is active, the drive is active as long as no
obstruction is detected or the end position is not reached, but it stops instantly,
if the control input becomes inactive.
2. Motor type
Set switch according to used motor.
3. Maximum speed
Set this switch to ON, if the drive should run in reduced speed only.
4. Motor generation
Set switch according to used motor.
Description
OFF
Deadman's
Semi
control
automatic
Prometheus
Motor type
XS/80/MT
Maximum speed
normal
Motor generation
XS-2
24V motor control device for flush box mounting - Version 1.1
ON
Deadman's
control
Prometheus
XS/120/MT
reduced
XS