GRUNDFOS INSTRUCTIONS MGE motors Installation and operating instructions MGE motors Installation and operating instructions Other languages http://net.grundfos.com/qr/i/98246988...
Page 3
MGE motors English (GB) Installation and operating instructions ............4 Deutsch (DE) Montage- und Betriebsanleitung .
Disposing of the product ..............72 1. General information 1.1 Hazard statements The symbols and hazard statements below may appear in Grundfos installation and operating instructions, safety instructions and service instructions. DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious personal injury.
The motors incorporate a functional module. The functional module is available in various versions with different inputs and outputs. You can fit the motors with a Grundfos add-on communication interface module (CIM). The module enables data transmission between the motor and an external system, for example a BMS or SCADA system. The module communicates via fieldbus protocols.
Environmental type Production code (year and week) Supply voltage [V] Rated power output [kW] Power board Functional module type CE mark and approvals Part number of the nameplate Grundfos logo Grundfos company address Country of origin Human Machine Interface type...
Page 8
Complete motor unit with terminal box Type of motor unit Basic motor unit without terminal box Kit for basic motor unit without terminal box Motor Grundfos Electronic control Frame size according to IEC, centre line height of the motor shaft in mm, foot-mounted motor...
Only for 3 x 200-230 VAC. 2.7 Identification of the functional module You can identify the fitted module in one of the following ways: Grundfos GO Remote You can identify the functional module in the Fitted modules menu under Status. Motor display For motors fitted with the advanced operating panel, you can identify the functional module in the Fitted modules menu under Status.
6.10 "Signal relay" ("Relay outputs") 2.8 Identification of the operating panel You can identify the operating panel in one of the following ways: Grundfos GO Remote You can identify the operating panel in the Fitted modules menu under Status. Motor display For motors fitted with the advanced operating panel, you can identify the operating panel in the Fitted modules menu under Status.
Attach lifting equipment to the motor eyebolts. Do not lift the product by the terminal box. 4.1.2 Cable entries The cable entries are fitted with blanking plugs from the factory. You can order various cable glands from Grundfos as accessory kits. Related information 8.5.5 Cable entry sizes 4.1.3 Cooling the motor...
Page 12
• Provide the product with a suitable cover. The cover must be large enough to ensure that the product is not exposed to direct sunlight, rain or snow. Grundfos does not supply covers. When fitting a cover to the product, observe the instructions for adequate cooling.
Page 13
Remove the terminal box cover. Press and hold in the two locking tabs (A) while gently lifting the plastic cover (B). Turn the plastic cover 180 °. Do not twist the cable more than 90 °. 180 ° Position the plastic cover correctly over the four rubber pins (C). Make sure that the locking tabs (A) are placed correctly. Fit the terminal box cover and make sure that it is turned 180 °...
Tighten the four screws (TX25) with 5 Nm. 4.2 Electrical installation DANGER Electric shock Death or serious personal injury ‐ Switch off the power supply to the product including the power supply for the signal relays. Wait at least 5 minutes before you make any connections in the terminal box.
Page 15
Check that the supply voltage and frequency correspond to the values stated on the nameplate. If you want to supply the product through an IT network, make sure that you have a suitable product variant. If you are in doubt, contact Grundfos. Mains connection on a single-phase motor Pos.
Page 16
If you want to supply the product through an IT network, make sure that you have a suitable product variant. If you are in doubt, contact Grundfos. Only the following motors can be supplied through an IT network: • Motors with a speed of 1450-2000/2200 rpm and up to 1.5 kW •...
Page 17
Connection example for three-phase supply The drawing shows an example of a mains-connected three-phase motor with a main switch, a backup fuse and a residual-current circuit breaker, type B. Pos. Description Residual-current circuit breaker, type B Phase 1 Phase 2 Phase 3 Protective earth 4.2.6.1 Overvoltage and undervoltage protection...
Page 18
• two analog inputs • two digital inputs or one digital input and one open-collector output • Grundfos Digital Sensor input and output • two signal relay outputs • GENIbus connection. The inputs and outputs are internally separated from the mains-conducting parts by reinforced insulation and galvanically separated from other circuits.
Page 19
Connection terminals for the mains supply Phases Terminals Single-phase N, PE, L Three-phase L1, L2, L3, PE Connection terminals for inputs and outputs DANGER Electric shock Death or serious personal injury ‐ Make sure that the wires to be connected to the connection groups below are separated from each other by reinforced insulation in their entire lengths.
Page 20
• one analog output • two dedicated digital inputs • two configurable digital inputs or open-collector outputs • Grundfos Digital Sensor input and output • two Pt100/1000 inputs • LiqTec sensor inputs • two signal relay outputs •...
Page 21
+24 V* DI4/OC2 Pt100/1000 Pt100/1000 +5 V* +24 V* +24 V*/5 V* +24 V* LiqTec LiqTec +24 V* DI3/OC1 +24 V* +24 V* +24 V*/5 V* +5 V GENIbus A GENIbus Y GENIbus B +24 V +24 V +5 V GDS TX +24 V* +24 V*...
Page 22
Grundfos Eye is off The power is off. Operation Pump running Ready Alarm Warning Operating mode Grundfos Eye is rotating green The pump or motor runs in Normal mode in open or closed loop. Operation Pump running Ready Alarm Warning Operating mode Normal Min.
Page 23
Operation Pump running Ready Alarm Warning Operating mode Manual Grundfos Eye is permanently green The pump or motor is ready for operation but is not running. Operation Pump running Ready Alarm Warning Operating mode Stop Grundfos Eye is rotating yellow Warning, but the pump or motor is running.
Page 24
Grundfos Eye is rotating red Alarm, but the pump or motor is running. Operation Pump running Ready Alarm Warning Operating mode Manual Grundfos Eye is flashing red The pump or motor has been stopped due to an alarm. Operation Pump running...
Page 25
Contact Grundfos for further information. If you use a bus signal, the local settings made via Grundfos GO Remote or the advanced operating panel will be overruled.In case the bus signal fails, the product will run with the local settings made via Grundfos GO Remote or the advanced operating panel.
Page 26
Remove the CIM (Communication Interface Module) cover (C1) by pressing the locking tab (D) and lifting the end of the cover (C2). Then lift the cover off the hooks (C3). Remove the screw (E). Fit the module by aligning it with the three plastic holders (F) and the connection plug (G). Press the module home, using your fingers. Fit and tighten the screw (E) to 1.3 Nm.
Page 27
Route the wires for the module through one of the cable glands. Fig. MGE 71, 80, 90 Fig. MGE 100, 112, 132, 160 Fit the CIM cover. 10. If the module is supplied with an FCC label, fix the label on the terminal box.
Electric shock Death or serious personal injury ‐ If the operating panel is cracked or perforated, replace it immediately. Contact the nearest Grundfos sales company. You can change the settings by means of the user interfaces listed below. Variant Designation...
Page 29
Light fields for indication of the setpoint. Up/Down: The buttons change the setpoint. Radio communication: The button enables radio communication with Grundfos GO Remote and other products of the same type. Start/Stop: Press the button to make the product ready for operation or to start and stop the product.Start: If you press the button when the product is stopped, the product starts if no other functions with higher priority have been enabled.Stop: If...
Page 30
- Press the Start/Stop button. - Press and hold the Down button until all light fields are off. - Use Grundfos GO Remote. - Use a digital input set to External stop. 5.1.2.7 Resetting alarms and warnings in products with a standard operating panel •...
Page 31
When you try to establish radio communication between the product and Grundfos GO Remote or another product, the green indicator light in Grundfos Eye flashes. In the controller display, a note states that a wireless device wants to connect to the product. Press OK on the product operating panel to allow radio communication with Grundfos GO Remote and other products of the same type.
Page 32
5.1.3.1 Home display Home Status Settings Assist Setpoint Control mode 5.00 bar Const. pressure Operating mode Actual controlled value Normal 4.90 bar Status Settings Assist Setpoint Control mode 5.00 bar Const. pressure Pos. Symbol Description Home: This menu shows up to four user-defined parameters. You can access each of the parameters directly from this menu.
Page 33
Status Multimotor system Analog input 2 • • • • Analog input 3 • • Pt100/1000 input 1 • • Pt100/1000 input 2 • • Analog output Warning and alarm • • Actual warning or alarm • • Warning log •...
Setup of multi-pump system • • Description of control mode • • Assisted fault advice • • Related information 6. Setting the product 5.2 Grundfos GO Remote The product is designed for wireless radio or infrared communication with Grundfos GO Remote.
Page 35
On products fitted with an advanced operating panel, the display indicates that a wireless device is trying to connect to the product. Press OK on the operating panel to connect the product with Grundfos GO Remote, or press the Home button to reject connection.
Page 36
5.2.1.2 Infrared communication Infrared communication can take place at distances up to 2 m. When communicating via infrared light, Grundfos GO Remote must be pointed at the operating panel of the product. Related information 5.2 Grundfos GO Remote 5.2.1 Communication 5.2.1.1 Radio communication 5.2.2 Menu overview for Grundfos GO Remote...
Page 37
Settings Multimotor system Pipe-filling function • • Buttons on product • Stop at min. speed • Controller • • Operating range • • Ramps • Number • Radio communication • Analog input 1 • Analog input 2 • Analog input 3 •...
• • Related information 6. Setting the product 5.3 Grundfos Eye The operating condition of the motor is indicated by Grundfos Eye on the motor operating panel. Grundfos Eye indicator light Indicator light Description The power is off. No lights are on.
You can set control functions via Grundfos GO Remote or the advanced operating panel. • If only one function name is mentioned, it refers to both Grundfos GO Remote and the operating panel. • If a function name is mentioned in a parenthesis, it refers to a function on the advanced operating panel.
6.5 "Control mode" You can choose between the following control modes: • Const. other val. (constant other value) • Const. curve (constant curve) Related information 5.1.2.2 Setting the setpoint in constant curve mode 5.1.2.1 Setting the setpoint in constant parameter mode 6.1 "Setpoint" 6.13 "Operating range"...
Page 41
Measured parameter Select one of the below parameters to be measured in the system by the sensor connected to the input. DPT DTT Sensor function/measured parameter Pos. Inlet pressure Diff. press., inlet Discharge press. Diff. press.,outlet Diff. press.,pump Press. 1, external Press.
• 0-5 V • 0-10 V • 0-20 mA • 4-20 mA. Sensor range, minimum value Set the minimum value of the connected sensor. Sensor range, maximum value Set the maximum value of the connected sensor. Related information 6.6.1 Setting two sensors for differential measurement 6.6.1 Setting two sensors for differential measurement Two analog sensors must be installed and connected electrically to measure a parameter at two different locations in a system.
Sensor function/measured parameter Pos. Liquid temp. Temperature 1 Temperature 2 Ambient temp. Not shown Measuring range -50 to +204 °C 6.8 "Digital inputs" The inputs and outputs available depend on the functional module fitted in the motor. Digital input 1 Digital input 2 Functional module (Terminals 2, GND)
Related information 2.7 Identification of the functional module 4.2.4 Connecting an external switch 6.8.1 Timer function for a digital input 6.9 "Digital inputs/outputs" 6.10 "Signal relay" ("Relay outputs") 6.15 "Predefined setpoints" 6.49 Priority of settings 6.8.1 Timer function for a digital input Activation delay The activation delay (T1) is the time between the digital signal and the activation of the selected function. Range: 0-6000 seconds.
Digital input/output 3 Digital input/output 4 Functional module (Terminals 10, GND) (Terminals 11, GND) FM 100 (basic) • FM 200 (standard) • FM 300 (advanced) • • You can select whether the interface is to be used as input or output. The output is an open collector. You can connect the open collector to, for example, an external relay or a controller such as a PLC.
Signal relay Functional module (Terminals 12, GND) FM 100 (basic) FM 200 (standard) FM 300 (advanced) • Functions You can configure the signal relays to be activated when the product changes to one of the following states: • Not active The relay has been deactivated.
Function of analog output Actual speed 100 % 10 V 0 mA 20 mA 4 mA 20 mA Sensor value Minimum Maximum 10 V 0 mA 20 mA 4 mA 20 mA Resulting setpoint 100 % 10 V 0 mA 20 mA 4 mA 20 mA...
If the advanced functional module type FM 300 is fitted, you can also influence the setpoint via one of the Pt100/1000 inputs. To enable the function, set one of the analog inputs or Pt100/1000 inputs to Setpoint influence with Grundfos GO Remote or to Ext.
Page 49
Pos. Description External input signal from 0 to 100 % Setpoint influence from 0 to 100 % Actual input signal, 60 % Sensor maximum [bar] Setpoint [bar] Actual setpoint [bar] Sensor minimum [bar] Example of a constant curve with linear influence function Actual setpoint: actual input signal x (setpoint - user-set minimum speed) + user-set minimum speed.
Pos. Description External input signal from 0 to 100 % Setpoint influence from 0 to 100 % 6.14.1.2 "Linear with stop" In the input signal range from 20 to 100 %, the setpoint is influenced linearly. If the input signal is below 10 %, the motor changes to the Stop operating mode.
Actual setpoint Normal setpoint Stop Stop If all digital inputs are open, the motor stops or runs at the normal setpoint. Set the desired action with Grundfos GO Remote or with the advanced operating panel. Related information 6.8 "Digital inputs" 6.49 Priority of settings 6.16 "Limit-exceeded function"...
• Stop The pump stops. • Min. The pump reduces the speed to minimum speed. • Max. The pump increases the speed to maximum speed. • User defined speed The pump runs at a speed set by the user. • Alarm and Stop An alarm is given and the pump stops.
6.18 "Ramps" The ramps determine how quickly the product can accelerate and decelerate during start and stop or setpoint changes. You can make the following settings: • acceleration time, 0.1 to 300 s • deceleration time, 0.1 to 300 s. The times apply to the acceleration from 0 rpm to a fixed maximum speed and the deceleration from a fixed maximum speed to 0 rpm, respectively.
Affected inputs: • Analog input 1 • Analog input 2 • Analog input 3 • Built-in Grundfos sensor • Pt100/1000 input 1 • Pt100/1000 input 2 • Liqtec input 6.23 "Motor bearing monitoring" Use this function to select whether or not you want to monitor the motor bearings.
Use this function to disable the option to make settings for protective reasons. • If you use Grundfos GO Remote and set the buttons to Not active, the buttons on the standard operating panel are disabled, except the Radio communication button.
You can change the code in the Connection code menu at any time. The old code is not required. 6.38.2 Setting a preset connection code in Grundfos GO Remote You can set and store a preset connection code in Grundfos GO Remote so that it automatically connects to products with an identical code. Open Grundfos GO Remote.
With the advanced operating panel, access the Assisted pump setup menu. 6.44 "Setup, analog inputs" The function is only available in the advanced operating panel. • Analog inputs, follow on-screen instructions. • Pt100/1000 inputs, follow on-screen instructions. Related information 6.12 "Controller" ("Controller settings") 6.45 "Setting of date and time"...
Page 58
19. Confirm the setting by pressing Send. 20. When you have finished the setup and the dialog box disappears, wait for the green indicator light in the middle of Grundfos Eye to light 6.46.4.2 Setting a multipump or multimotor system with Grundfos GO Remote and a wired motor connection Connect the two motors with each other with a 3-core screened cable between the GENIbus terminals A, Y, B.
Page 59
22. Confirm the setting by pressing Send. 23. When you have finished the setup and the dialog box disappears, wait for the green indicator light in the middle of Grundfos Eye to light 6.46.4.3 Setting a multipump or multimotor system with the advanced operating panel and a wireless motor connection Power on both motors.
If two or more functions are enabled at the same time, the motor operates according to the function with the highest priority. If you have set the motor to maximum speed via the digital input, the motor operating panel or Grundfos GO Remote can only set the motor to Manual or Stop.
Start Stop and Maximum speed settings made with Grundfos GO Remote or on the motor operating panel can be overruled by another operating-mode command sent from a bus, for exampleStart. If the bus communication is interrupted, the motor resumes its previous operating mode, for example Stop, that was selected with Grundfos GO Remote or the motor operating panel.
‐ Do not handle the motor or rotor if you have a pacemaker. If service of the product is required, contact Grundfos. 7.1 Insulation resistance test Do not use a megger or similar high voltage instrument, as the built-in electronics may be damaged.
8.2 Technical data, three-phase motors DANGER Electric shock Death or serious personal injury ‐ Use the recommended fuse size. Supply voltage • 3 x 380-500 V - 10 %/+ 10 %, 50/60 Hz, PE • 3 x 200-240 V - 10 %/+ 10 %, 50/60 Hz, PE. Check that the supply voltage and frequency correspond to the values stated on the nameplate.
Use Pt1000 for long wires. LiqTec sensor inputs Use a Grundfos LiqTec sensor only. Screened cable: 0.5 - 1.5 mm / 28-16 AWG. Grundfos Digital Sensor input and output (GDS) Use Grundfos Digital Sensor only. Power supplies, +5 V, +24 V +5 V •...
Page 66
1450 - 2000/2200 rpm Supply voltage Power [kW] L [mm] W [mm] H [mm] Weight [kg] 0.25 10.1 0.37 10.1 1 x 200-230 V 0.55 11.9 0.75 12.7 0.25 11.8 0.37 11.8 0.55 13.7 0.75 14.4 16.3 3 x 380-500 V 296.7 28.2 296.7...
Page 67
Supply voltage Power [kW] L [mm] W [mm] H [mm] Weight [kg] 13.6 296.7 21.9 3 x 200-240 V 296.7 296.7 364.5 41.7 Motor with tapped-hole flange (FT), B14 1450 - 2000/2200 rpm Supply voltage Power [kW] L [mm] W [mm] H [mm] Weight [kg] 0.25...
4000-5900 min 0.25 0.37 0.55 0.75 C3/C1 C3/C1 C3/C1 C3/C1 C1, if equipped with an external Grundfos EMC filter. Immunity: The motor fulfils the requirements for industrial areas. Contact Grundfos for further information. 8.5.2 Enclosure class Standard: IP55 (IEC 34-5).
Page 69
Optional: IP66 (IEC 34-5). 8.5.3 Insulation class F (IEC 85). 8.5.4 Standby power consumption 5-10 W. 8.5.5 Cable entry sizes Number and size of cable entries Motor [kW] 1450-2200 min 2900-4000 min 4000-5900 min 0.25 - 1.5 4 x M20 4 x M20 4 x M20 1 x M25 + 4 x M20...
Page 70
Sound pressure level Rated maximum ISO 3743 Motor speed Speed [min [dB(A)] [kW] [min 1 x 200-240 V 3 x 200-240 V 3 x 380-500 V 1500 2000 2000 3000 4000 4000 4000 5900 5900 1500 2000 2000 1500 2200 2000 3000 4000...
The motor can operate with the rated power output (P2) at 50 °C. Continuous operation at higher temperatures reduces the expected product life. If the motor operates at ambient temperatures between 50 and 60 °C, select an oversized motor. Contact Grundfos for further information.
Use the public or private waste collection service. If this is not possible, contact the nearest Grundfos company or service workshop. Dispose of the waste battery through the national collective schemes. If in doubt, contact your local Grundfos company. See also end-of-life information at www.grundfos.com/product-recycling.
Page 73
• This device must accept any interference, including interference that may cause undesired operation of the device. Users are cautioned that changes or modifications not expressly approved by Grundfos could void the user's authority to operate the equipment. Pour le Canada Ce dispositif est conforme à...
Page 74
Location of identification numbers Stop Identification numbers Identification numbers A.1.4. Electrical connection Conductors 4.2.5 Cable requirements. Torques 8.5.6 Torques for terminals. Line reactors The maximum line reactor size in front of the drive must not exceed the following values: Maximum line reactor [kW] [mH] 1450-2000 rpm...
Page 75
Tel.: +387 33 592 480 Centre Turkey Fax: +387 33 590 465 29-33 Wing Hong Street & 68 King Lam GRUNDFOS Pumper A/S GRUNDFOS POMPA San. ve Tic. Ltd. Sti. www.ba.grundfos.com Street, Cheung Sha Wan Strømsveien 344 Gebze Organize Sanayi Bölgesi E-mail: grundfos@bih.net.ba...