Technical Data Outline Drawing MS 402 Product data Dimensions and Weights MS 402 Outline Drawing MS 4000 Introduction Dimensions and Weights MS 4000 Grundfos MS Motors Introduction Outline Drawing MS 6000 MS Motor Selection Dimensions and Weights MS 6000 Product Range...
Mission - to successfully develop, produce, and sell high quality motors and pumping systems worldwide, contributing to a better quality of life and healthier environment GBJ - Bjerringbro, Denmark GMU - Fresno, California GPU - Olathe, Kansas GMX - Monterrey, Mexico GPA - Allentown, Pennsylvania GCA - Oakville, Ontario •...
The motor and power cable are designed and sealed to its entire operating range. Grundfos 4” and 6” submers- prevent water from contacting any part of the electrical ible motors are built to NEMA standards, which define circuit.
Product data MS Motors Product Range MS 402 MS 4000 (R) MS 6000 (R) Motor size 4" 4" 6" Power range, direct-on-line - 1 x 115 V - 1 x 230 V .33 - 1.50 .25 - 1.1 2.0 - 5.0 1.5 - 4.0...
Features MS Motors MS 402 • Complete Range of Motors from 1/3 - 2 Hp 1 ph, 2-wire ; 3-wire and 3 Ph. • Designed for 4" and Larger Wells • Corrosion Resistance All Stainless Steel Exterior Construction • Cast Stainless Steel Machined Top •...
Features MS Motors MS 4000 • Complete Range of Motors from 3 - 10 Hp 1 ph, 3-wire and 3 Ph. • Designed for 4" and Larger Wells • Corrosion Resistance All Stainless Steel Exterior Construction • Stainless Steel Splined Shaft •...
Features MS Motors MS 6000 • Complete Range of Motors from 7 1/2 - 40 Hp 3 Ph • Designed for 6" and Larger Wells • Corrosion Resistance All Stainless Steel Exterior Construction • Stainless Steel Splined Shaft • Stator Windings Hermetically Encapsulated in Stain- less Steel •...
Operating Conditions MS Motors Operating Conditions Cooling The cooling of the motor depends on the temperature and the flow velocity of the pumped liquid past the motor. To ensure sufficient cooling, the values for maximum temperature of the pumped liquid and its flow velocity must be kept.
Page 11
In case the actual temperature of the pumped liquid is higher than the one stated in the table, or if the oper- ating conditions are especially unfavourable, please contact Grundfos. ø95 Free Convection Free convection is achieved when the diameter of the borehole is at least 2"...
Page 12
Pumped Liquids The MS 4000 motors are available in several versions to enable use in various liquids. • MS 4000 is generally recommended for use in water without chloride. MS 4000 is made of 304 stainless steel AISI • MS 4000 R is recommended for use in aggressive liquids.
Page 13
• MS 6000 RE is recommended for use in aggressive and slightly contaminated liquids. MS 4000 RE is made of 904 stainless steel AISI, and the rubber parts are made of FKM. In cases of doubt, please make an analysis of the liquid and contact Grundfos.
Construction MS Motors Material specification for MS 402 Example: MS 402 Standard Version Pos. Component Material AISI Plug Plastics, PELD Shaft Stainless steel Stop ring (upthrust) Polyethylene, PP Housing for radial bearing Silumin Radial bearing, Ceramic stationary Bearing journal Tungsten carbide Filling compound Polyurethane Stator sleeve...
Construction MS Motors Material specification for MS 4000 Example: MS 4000 Standard Version Pos. Component Material AISI Stator Stainless steel Rotor Stainless steel Thrust bearing, (stationary) Carbon Radial bearing, complete Ceramic Bearing pipe, complete Cast iron GG20 Thrust bearing, (rotating)
Construction MS Motors Material specification for MS 6000 Example: MS 6000 Standard Version Pos. Component Material AISI Stator Stainless steel Rotor Stop ring PTFE Thrust bearing, (stationary) Carbon Ceramic/tungsten Radial bearing, lower carbide Ceramic/tungsten Radial bearing, upper carbide Thrust bearing (rotating) Clamping flange Steel Thrust cover...
Selection MS Motors Motor Operation The synchronous speed on any motor can be calcu- lated when the number of poles and operating Most deep well submersible type pumps are powered frequency is known, using the formula below: by electric motors. The optimum power unit used is N = f x 120/P where;...
Selection MS Motors Motor Efficiency Most electrical utilities guarantees voltages to a +/-5 percent standard; for "480" service voltage will be An electric motor operates at a relatively constant effi- between 456 V and 504 V at the meter; for "240" ciency and speed over a wide range of loadings.
Selection MS Motors • Materials of Construction. Submersible pumps Application and Selection Issues and motors are also selected based on the chemical The term application not only refers to the end use of and physical make-up of the water in which they will the product but also the parameters which affect the be submerged.
Grundfos When the ambient temperature exceeds the tempera- Submersible Motors are designed to operate at full load ture at which the motor performance is based, the in water up to 30°C (86°F) free convection, and 40C...
Mechanical Installation MS Motors Shroud/Flow Inducer Sleeve/ A fluid velocity of 3 fps is generally considered optimum and 0.5 fps is the minimum cooling velocity value. Cooling Sleeve The actual fluid velocity past the motor can be calcu- On some installations it is necessary to use a shroud to lated using the formula: insure that all, or some portion of the produced fluid Velocity (past motor) = gpm/2.45 (ID casting)
In MS 402 - 4" Min. 1 pr. year addition to focusing the pumped fluid to dissipate motor MS 4000 - 4" Max. 100 pr. hour heat, a motor shroud can be used to improve suction MS 6000 - 6"...
Page 23
Mechanical Installation MS Motors Cooling Sleeve - Horizontally Installed Motor in a Tank Cooling Sleeve - Vertically Insulated Motor in Tank Water level Min. 1.5 ft W/O Cooling Shroud Baffle Plate Vortex Fig. 8 Vertical Flow Seen from above Cross section Water level Vortex Baffle Plate...
Electrical Installation MS Motors Submersible Power Cable Typical conductor insulation materials are synthetic rubber (RW, RUW, TW, etc.), plastic (PVC, XPLE, etc.) Power is transmitted from the starter/controller to the or special polymer (FPE, hypalin, EPR - EPDM, etc.). submersible motor through a marine duty power cable, Special cable insulations are often recommended or typically consisting of three flexible stranded conduc- required for sever duty or special applications such as;...
The use of power cables smaller than the as rubber compounds typically used in there construc- minimum sizes as permitted by code or recommended tion will set with time, making a water tight connection by Grundfos will generally void the motor warranty. difficult. Grundfos installation...
Electrical Data MS Motors Transformer Capacity Required for Three-Phase Motors Submersible Smallest KVA Rating - Each Transformer Three-Phase Total Effective Open WYE or DELTA WYE or DELTA Motor HP Rating KVA Required 2 Transformers 3 Transformers Pump Motor KVA requirements only - does not include allowances for other loads. This is also the KVA required for single phase motors.
Electrical Data MS Motors Engine-Driven Generators Required for Submersible Motors Minimum kW Rating of Generator Sub Motor HP Externally Regulated Internally Regulated Single or Three Phase 1/3 Hp 1/2 Hp 3/4 Hp 1 Hp 3.13 1 1/2 Hp 6.25 2 Hp 3 Hp 10.0 12.5...
Accessories MS Motors CU 3 CU 3 The CU 3 control unit is an electronic motor starter for R100 monitoring and protecting installations with rated volt- ages of 200-575 V, 50 - 60 Hz, and a maximum power consumption of 400 A. The CU 3 monitors the following parameters: •...
Accessories MS Motors Technical data Enclosure class: IP 20. Ambient temp.: –20°C to +60°C. Relative humidity: 99%. Voltage variation: –25/+15% of nominal voltage. Frequency: 45 Hz to 65 Hz. Max. back-up fuse: 10 A. Relay output: Max. 415 V, 3 A, AC 1. Approvals: The CU 3 complies with: VDE, DEMKO, EN, UL and CSA.
Accessories MS Motors Control functions This table describes the protection provided by CU 3. Control Function Problem Advantages parameters Ground failure Insulation resistance is measured only Damaged decom- Possibility of failure when motor is not operating. posed insulation indication on motor, motor, cable or cable cable and cable joint, A high-impedance voltage is applied to the...
Time Using the Grundfos CU 3 control unit and a sensor it is possible to measure water conductivity in each bore- hole. This provides for the possibility of selecting the borehole (or boreholes) to be in operation which supplies the best water quality at any time.
Accessories MS Motors Motor protection via CU 3 Control unit CU 3 with R100 remote control and printer • Power on • Motor on • Power on • Motor temperature • Motor on • Ground failure • Motor temperature • Overload/dry running •...
Accessories MS Motors Status report R100 Menus 0. General All settings and measured values can be transferred to a portable printer via wireless infra-red communication 1. Operation and be printed in a status report. 1.1 Warning and stop indication. 1.2 Indication of automatically reset fault indications. Possibility of start and stop.
Accessories MS Motors Menu Structure of the R100 Remote Control Start Contrast Light 1. Operation 2. Status 3. Limits 4. Installation 0. General 2.10 4.10 2.11 4.11 4.12 2.12 2.13...
• Overload/dry running • Overvoltage/undervoltage SM100 Protokoll- • Current unbalance umsetzer (bauseits) • Direction of rotation GRUNDFOS-GENIbus max. 1200 m (not supplied with the unit) Fig. 23 Maximum connection to the GENIbus: Gateway CU 3 SM 100 (not supplied with •...
Further product documentation Sources of product documenta- tion In addition to the printed data booklet, Grundfos offers the following sources of product documentation. • WinCAPS • WebCAPS. WinCAPS® WinCAPS Windows-based Computer-Aided Product Selection program containing information on more than 90,000 Grundfos products.
Further product documentation WebCAPS® WebCAPS is a Web-based Computer Aided-Product Selection program and a web-version of WinCAPS. Available on Grundfos’ homepage, www.grundfos.com, WebCAPS offers • detailed technical information • dimensional drawings of each pump • wiring diagrams of each pump.
Page 48
Innovation is the essence L-MS-PG-001 01/05 Subject to alterations. GRUNDFOS Pumps Corporation GRUNDFOS Canada Inc. Bombas GRUNDFOS de Mexico S.A. de C.V. 17100 West 118th Terrace 2941 Brighton Road Boulevard TLC No. 15 Olathe, Kansas 66061 Oakville, Ontario L6H 6C9 Canada...