Receiving the product... . 7 The symbols and hazard statements below may appear in Grundfos installation and operating Mechanical installation ... 8 instructions, safety instructions and service Lifting the product .
This manual applies to all the standard series of A red or grey circle with a diagonal bar, MMG-H and various series of motors derived from it. possibly with a black graphical symbol, Frame size: 56-355. (For some special designed indicates that an action must not be taken types of motors or those for special applications, it or must be stopped.
Page 6
Internationa Title CENELEC CEI-EN DIN/VDE Terminal markings and direction of IEC 60034-8 EN 60034-8 CEI 2-8 BS 4999-3 NFC 51-118 VDE 0530-8 rotation for electrical machines CEI-EN Noise emission, limit IEC 60034-9 EN 60034-9 50034-9 (CEI BS 4999-51 NFC 51-119 VDE 0530-9 values 2-24)
5. Mechanical installation Excessive tension of the belts causes harmful radial loads on the motor shaft and bearings, reducing their Work on the electric machine must be life. carried out when the machine has stopped and been disconnected from the power Excessive tension of the belts causes supply (including auxiliary parts, such as harmful radial loads on the motor shaft and...
Do not apply a tension over 6 V during the thermistor continuity test. Anticondensation If the motor is fitted with anticondensation heaters, their power supply must be separated from that of the motor, using the terminals housed in the terminal box. The supply of the heater is always mono- phase and the voltage is different from that of the motor.
6. Electrical connection Number of poles: 2/6, 2/8, 4/6, 6/8, etc. Synchronous speed at 50 Hz: 3000/1000, 3000/750, 1500/1000, 1000/750, etc. 6.1 Wiring diagrams Dahlander system for two-speed motors, constant Connection for single-speed motors torque Y-connection High speed D-connection Low speed Number of poles: 2, 4, 6, 8.
7. Startup Number of poles: 2/4, 4/8. Synchronous speed at 50 Hz: 3000/1500, 1500/750. It is the responsibility of the installer to determine Connection for single-phase and special motors whether the motor is suitable to be used in a certain plant, after analysing the characteristics of danger For single-phase motors and motors with special existing in the installation area with respect to current...
• Load type: carefully evaluate the high moments of If you intend to start the motor by means of static inertia and the relative starting time of the motor. starters, rheostats or the star-delta system, they must be chosen and set properly to avoid incorrect •...
8. Service 8.1.7 Thermal protection Make sure that thermal protections have not cut out Any operation on the motor must be carried out with and have been set properly. the machine stopped and disconnected from the power supply (including auxiliary circuits, especially 8.1.8 Unauthorised modifications the anticondensation heaters).
In this case, it is necessary to specify these authorised service workshop. For further information, particular storage conditions during the ordering contact your local Grundfos sales company. stage so that proper precautions can be taken during building and packaging.
10. Fault finding the product 10.1 The motor does not start Cause Remedy Fuses damaged due to start overloading • Replace the fuses with similar ones of the correct size. Opening of the overload switch • Check and reset the switches. Insufficient power available •...
Cause Remedy Cooling fins and/or fan cover blocked by dirt • Clean the ventilation slots to ensure a continuous flow of air over the motor. One phase on the motor is down • Check that all the cables are connected tightly and correctly.
1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. The crossed-out wheelie bin symbol on a product means that it must be disposed of separately from household waste.
Page 19
Argentina China Greece Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Hellas A.E.B.E. Ruta Panamericana km. 37.500industin 10F The Hub, No. 33 Suhong Road 20th km. Athinon-Markopoulou Av. 1619 - Garín Pcia. de B.A. Minhang District P.O. Box 71 Tel.: +54-3327 414 444...
Page 20
Fax: +66-2-725 8998 Fax: + 370 52 395 431 Москва, RU-109544, Russia Turkey Тел. (+7) 495 564-88-00 (495) 737-30-00 Malaysia GRUNDFOS POMPA San. ve Tic. Ltd. Факс (+7) 495 564 8811 GRUNDFOS Pumps Sdn. Bhd. Sti. E-mail grundfos.moscow@grundfos.com 7 Jalan Peguam U1/25 Gebze Organize Sanayi Bölgesi...
Need help?
Do you have a question about the MMG-H IE4 and is the answer not in the manual?
Questions and answers