C 1 .lO)
Setting and resetting
of a ma.rker
With the aid of the command
S or SN, a marker
can be set, cependent
upon the preceding
logic result.
With the aid of the command
R or RN, a marker
can be rese.:, dependent
uipon the preceding
logic result.
Function
1
Ybbreviation
Set marker
or output
if previous
gating result
is "1 "
-
Set marker
or output
if previous
gating result
is "0"
S
SN
Reset marker
or output
if previous
gating result
is "1 "
-
Reset marker
or output
if previous
gating result
is "0"
-
R
RN
Examples:
a)
Setting
a marker
Symbol
-
L
PLC-Programme
U
El
U
Ml0
S
Ml5
U
El
U Ml1
SN Ml6
U Ml0
R Ml6
U Ml1
RNM15
PLC-Programme:
U E'25
U M33
u M61
S M300
If input 25 and markers
33 and 61 are logic "I",
then marker
300 will
be set to "1".
In contrast
to the
= - functions,
marker
300 remains
set even if the logic resul? in the next PLC-programme
cycle produces
logic
"0".
Normally,
the marker
is reset by the command
R or R~\I.
b)
Resetting
of a memory
location
PLC-Programme:
u El8
U E39
R M300