Display data usage
The following readings can each be used in place of dedicated sending units to the gauge control unit. These are individually
selectable in the display system gauge setup menus.
*Some gauge features require a minimum software revision or higher to be supported:
VHX
VFD3
VFD3X
VHX/VFD Setup:
Using speed from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show SETUP.
Release SW1. The message display should show SPEED.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
Using RPM from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show SETUP.
Release SW1. Press and release SW1 until TACH is displayed.
Press and hold SW1. The message display should show T CAL or ENGINE. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
Using engine temperature from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show SETUP.
Release SW1. Press and release SW1 until WATER is displayed.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS F or BUS C is displayed depending on your unit choice.
Press and hold SW1 until DONE is displayed.
Using oil pressure from the BIM-01-2 (if available)
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show SETUP.
Release SW1. Press and release SW1 until OIL is displayed.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
***Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the message center if activated through the display menu setup.
HDX setup (Can also be completed using the Bluetooth app):
Using speed from the BIM-01-2
With ignition on. Press and hold both switches to enter SETUP.
Press and release either switch until SPEED is selected. Press and hold either switch to enter SPEED menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch unit BIM is displayed. Press and hold either switch to select BIM.
Using RPM from the BIM-01-2
Press and hold both switches to enter SETUP.
Press and release either switch until TACH is selected. Press and hold either switch to enter TACH menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until CYLINDER is displayed. Press and hold either switch to select CYLINDER.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
Using engine temperature from the BIM-01-2
Press and hold both switches to enter SETUP.
Press and release either switch until WATER is selected. Press and hold either switch to enter WATER menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
Using oil pressure from the BIM-01-2 (if available)
Press and hold both switches to enter SETUP.
Press and release either switch until OIL is selected. Press and hold either switch to enter OIL menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
Oil Pressure
VX04
SE47
SE55