Download Print this page

Dakota Digital BIM-01-2-HLLY Manual page 2

Bus interface module for holley efi
Hide thumbs Also See for BIM-01-2-HLLY:

Advertisement

System Setup:
Terminator, HP and Dominator EFI system setup
Holley
For this to unit to function correctly with the Holley EFI system you will need to ensure the EFI system CAN settings are set to
"Racepak." These settings can be adjusted through Holley's computer software. To make this change select the 'System ICF'
tab, then 'Basic I/O'>>'CAN Bus'>>'CAN Bus 1 and 2 Type'. Select the dropdown and select "Racepak".
Sniper EFI system setup
For this to unit to function correctly with the Sniper EFI system you will need to enable the  (Sniper) option through the setup
menu. With the unit off, press and hold the button on the BIM. Cycle the ignition to the on position then release the button. Press
and release the button until  (Sniper) is displayed. Press and hold to enter the menu. Press and release the button until  is
shown. Press and hold to select.
Terminator, HP and Dominator EFI speed input
This module is programmed to monitor MPH broadcasted from Dominator and HP ECU's. By default, it is pre-programmed to
monitor the Dominator ECU speed input (J4 pin 18). It's also capable of monitoring HP and Dominator Input #1 (P1A pin A12)
for speed (F). To enable Input #1 speed monitoring, you must enable the  (Speed) option through the setup menu. With the
unit off, press and hold the button on the BIM. Cycle the ignition to the on position then release the button. Press and release the
button until  (Input) is displayed. Press and hold to enter the menu. Press and release the button until  is shown. Press
and hold to select.
EFI MAP/boost
This module is programmed to monitor MAP(PSI/inHg) and boost(PSI/inHg) data broadcasted on the Holley EFI. MAP and boost
will both be displayed with the boost label on our system. MAP is the default reading preset from the factory. If you wish to
monitor boost pressure you must enable the  (boost) option through the setup menu. With the unit off, press and hold the
button on the BIM. Cycle the ignition to the on position then release the button. Press and release the button until  (boost) is
displayed. Press and hold to enter the menu. Press and release the button until  is shown. Press and hold to select.
MAN #650588A