Installation Inspection and Testing
Error indicator
Display
Communication error between
indoor and outdoor units
Error on indoor temperature sensor
,
Error on indoor heat exchanger
Error on indoor fan motor
,
EEPROM/Option error
,
Refrigerant flow blocking error
Lack of refrigerant (for inverter
models only)
Step 4-8 Performing final checks and
trial operation
WARNING
Stop the unit, disconnect the power, and contact Samsung
technical support if any of the following occurs:
•
The unit produces a burning smell or smoke.
•
The power cable is hot or damaged.
•
The unit is very noisy.
•
Any foreign substance, such as water, has entered the
appliance.
•
The appliance becomes flooded.
28
English
Error
•
Check the cables between the indoor and outdoor units.
See if the power cable or communication cable is crossed.
•
Make sure that the indoor temperature sensor is properly
connected.
•
Make sure that the evaporator temperature sensor is
properly connected.
•
Make sure that the evaporator motor is properly
connected to the board.
•
Check for a foreign substance inside the unit that may be
preventing the blower wheel from turning.
•
Reset the option codes.
•
Make sure that the service valves are completely open.
•
Check for any blockage in the refrigerant pipe that
connects the indoor and outdoor units.
•
Check for refrigerant leaks.
•
Make sure a sufficient amount of refrigerant has been
added for a pipe that is longer than 7.5 m.
•
Check for refrigerant leaks between the valve and pipe
connection.
1
2
Measures for the installer to take
Check the following:
‐
Strength of the installation site
‐
Tightness of pipe connection to detect gas leak
‐
Electric wiring connection
‐
Heat-resistant insulation of the pipe
‐
Drainage
‐
Grounding conductor connection
‐
Correct operation (Take the following steps.)
Press the
(Power) button on the remote control to
check the following:
‐
The indicator on the indoor unit lights up.
‐
The airflow blade opens and the fan gears up for
operation.