INVERTER REMOTE CONTROL PANEL

The Inverter Remote Control Panel
cabinet above the coach entrance doorway. The Inverter
Remote Control Panel is equipped with an Inverter
Function - ON/OFF switch
System Status Display
different stages of Battery Charging, DC Power Usage
while Inverting and more information.
1. Fault
2
2. Status Display
3
3. Inverting LED
4
4. Inverter Function ON/OFF
1
3
Refer to the Inverter Remote Control manual in the
Motorhome Information Kit for more information.
  ᘐ NOTICE
The inverter remote control panel is factory-
configured for the specific inverter and battery
installed in your motorhome. If modifications are
made to the battery bank, it may be necessary to
reconfigure the remote. Have the inverter and
controls serviced by authorized personnel only.
is located in the
1
. The Inverter/Charger
5
shows the Battery Voltage,
3
5
4
2
5
ELECTRICAL SYSTEM OPERATION

SURGE GUARD (OPTIONAL)

When shore power is connected it passes through the
EMS-LCHW30 surge protection device to protect the
wiring in the Unity.
• Do not exceed the rating on the EMS for any reason.
These devices are designed to be reduced down to
120V/15A and maintain full protection.
• Do not modify the EMS in any way, as this will void the
warranty, compromise protection and could result
in possible shock and/or a fire hazard.
• It is important to always check the pedestal power
outlet for charring. Charring indicates the AC
receptacle is providing a weak connection. Should
this condition exists DO NOT USE as it could result
in possible melting of the RV power plug.
• All AC power extension cords in conjunction with your
EMS unit should be rated 10 gauge for 120V, 30A
systems and rated for outdoor use to reduce the risk
of electrical shock. We recommend the length not to
exceed 30' . Small gauge cable has higher resistance
and can result in voltage loss or an electrical fire.
• Whenever servicing or installing the EMS, or any
other AC powered device, make sure AC power is
disconnected.
• Refer to your floor plan in the "Introduction" section
for the surge protector location.