US Steam SeaHawk User Manual
Hide thumbs Also See for SeaHawk:

Advertisement

Quick Links

SeaHawk
User Manual
US Steam
7940 Rodeo Trail
Suite 360
Mansfield, Texas 76063
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SeaHawk and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for US Steam SeaHawk

  • Page 1 SeaHawk User Manual US Steam 7940 Rodeo Trail Suite 360 Mansfield, Texas 76063...
  • Page 3: Table Of Contents

    Descaling ________________________________________________________ Notices __________________________________________________________ Warranty & Repair _________________________________________________ 17 Congratulations on your purchase of the US Steam SeaHawk system. The SeaHawk not only combines a steam, extraction, and vacuum cleaner into one system, but it included our patented RAIN SYSTEM™.
  • Page 4: Components

    Components Carry Handle Extraction Bottle Steam Pressure Connector Control Vacuum Speed ON/OFF Control Technical Data: Steam Pressure: 4.5 Bars Air flow: 22 L/S Boiler Volume: .81 Liters Boiler Capacity: .4 Liters Recovery Tank: 1.2 Liters Extraction Bottle HEPA Filter Vacuum Collection Tank Steam Reservior Tank...
  • Page 5: Steam And Vacuum Controls

    Vacuum & Steam Controls Steam Controls Vacuum Controls Steam Pressure Control Increase Decrease Vacuum Power ON/OFF ON/OFF Low Water Max Speed Steam Light Medium (solid when ready) Vacuum Collection Tank is FULL Stand by Mode Ø Most cleaning jobs can be Ø...
  • Page 6: Quick Start

    Ø The SeaHawk should be the only appliance plugged into the power outlet. Ø Use only a 12 gauge / 15AMP rated or higher extension cord. Ø It will take 5 minutes for the SeaHawk to heat and be ready for use. 5) ON/OFF...
  • Page 7 REFILLING Ø When your SeaHawk needs refilling, the low water light comes on and the steamer will start beeping. Ø Turn off the SeaHawk and refill the steam reservoir tank. Push power button to restart your SeaHawk.
  • Page 8: Shut Down

    Ø Clean vacuum hose by activating the vacuum mode and suck water through the hose. To get the most utilization out of your new SeaHawk, have it ready to go at all times. After each cleaning, prep the SeaHawk by refilling all water and vacuum tanks so its ready to use.
  • Page 9: Trouble Shooting

    Trouble Shooting PROBLEM SOLUTION The SeaHawk should be the ONLY appliance plugged into the electrical outlet: Ø Check the fuse box for tripped circuit breaker. No Power Ø If using an extension cord it must meet the following requirements: Ø Minimum 12 gauge / 15AMP Ø...
  • Page 10: Tools & Accessories

    Accessories Extension Wands Nylon Brush Hose Handle Extraction Bottle Part # J11594 Part # Part # Part # ______________________________________________________ Hard floors (wood, tile) Rubber Insert Part # Carpets and rugs Floor Brush Part # Carpet Insert Part # J8157 ______________________________________________________ Suction Nozzle 3”...
  • Page 11 Extraction Accessories NO ATTACHMENT Carpet, upholstery, and mattress Glass, windows, and mirrors Brush: Rubber /Bristle Part # All hardwood surfaces Brush: Rubber /Rubber Part # J16023 Small Extraction Nozzle Part # J7314 Pre-Cleaning in heavy soiled area Nylon Brush Part # J7664 _____________________________________________________ NO ATTACHMENT Carpet, upholstery, and mattress...
  • Page 12: Maintenance

    ② Clean vacuum hose by activating the vacuum mode and suck water through the hose. ③ Clean the exterior of the SeaHawk with wet cloth. Do not use solvents or detergents that could damage the plastic surface. ④ Clean Vacuum Collection Tank Remove the tank and drain water from the vacuum and reservoir tanks.
  • Page 13 Check the O-rings on the connector for damage: You can order a suitable set of O-rings from our online shop at www.beam.de or by telephone on +49 (0)8337-7400-21. the bottom of the SeaHawk. Item no.: 96300 Pos(3): 2 O-rings on the brass spout Ø...
  • Page 15: De-Scaling

    ⑦ Empty the de-scaling solution from the boiler by turning over the SeaHawk and removing cap draining the excess descaling solution. ⑧ Fill steam reservoir tank with tap water and turn ON the SeaHawk allowing the boiler to fill completely. It should take about 1 minute to fill the boiler.
  • Page 16: Notices

    Notices Read all instructions before using this steam cleaner. WARNING: STEAM GENERATED BY THE SeaHawk IS EXTREMLY HOT AND WILL CAUSE INJURY IF IT COMES IN CONTACT WITH THE SKIN OR EYES. USE AS DIRECTED BY THE MANUAL AND ONLY AIM THE STEAM HANDLE AT THE CLEANING AREA.
  • Page 17: Warranty & Repair

    US Steam’s responsibility is limited to repair, replacement, credit or refund, any of which may be selected by US Steam at its sole discretion. The Warranty does not cover defects or damage arising from the disassembly or attempted disassembly of your steamer.
  • Page 18 Floors, Kitchen, Grills & Bathrooms Restaurant Chemical free cleaning in all food prep and storage areas. A Better Way to clean floors and bathrooms. Patient Beds, Wheel Chairs & Curtains Hospital Steam is a proven killer of virus and infection causing germs. Steam can sanitize areas too difficult to treat with chemicals.