Installation of indoor unit

Step one: choosing installation location
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
09、12K:
Wall
Mark in the middle of it
Space
to the
wall
above
150mm
Left
Rear piping hole
2. Open a piping hole with the diameter of
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
Wall
Level meter
Space
to the
wall
above
150mm
Right
Rear piping hole
2
18K:
Wall
Mark in the middle of it
Space
to the
wall
above
150mm
Left
Rear piping hole
rm it with the client.
.
Level meter
Space
to the
wall
above
150mm
Right
Rear piping hole
Wall