Connected Grid Module (CGM) WPAN-OFDM-FCC Module - Cisco IOS
Installation Guidelines
WARNING : No user-serviceable parts inside. Do not open. Statement 1073
WARNING : Ultimate disposal of this product should be handled according to all national laws and regulations. Statement
1040
WARNING : Do not locate the antenna near overhead power lines or other electric light or power circuits, or where it can
come into contact with such circuits. When installing the antenna, take extreme care not to come into contact with such
circuits, because they may cause serious injury or death. For proper installation and grounding of the antenna, please
refer to national and local codes (for example, U.S.:NFPA 70, National Electrical Code, Article 810, Canada: Canadian
Electrical Code, Section 54). Statement 1052
WARNING : This product is not intended to be directly connected to the Cable Distribution System. Additional regulatory
compliance and legal requirements may apply for direct connection to the Cable Distribution System. This product may
connect to the Cable Distribution System ONLY through a device that is approved for direct connection. Statement 1078
Note: The WPAN module can be installed in any slot of the CGR 1120. You should only install the WPAN module in slot
4 of the CGR1240 due to the physical constraints of the short antenna cable for the integrated WPAN antenna and for
adequate antenna isolation between WPAN and 3G cellular radios.
Before installing the CGM-WPAN-OFDM-FCC module, verify that the following guidelines have been met:
For a CGR 1240: Install the WPAN module only in slot 4. (This is due to the physical constraints of the short antenna
cable for the integrated WPAN antenna and to provide adequate antenna isolation between WPAN and 3G cellular
radios.)
For CGR 1120, you can install the CGM-WPAN-OFDM-FCC module in any slot.
Clearance on the I/O side allows a clear view of the LED.
Airflow around the module and through the vents is unrestricted.
Temperature around the unit does not exceed 140 degrees F (60 degrees C). Note: If you install the WPAN module
in a closed or multi-rack assembly, the temperature around it might be higher than normal room temperature.
Relative humidity around the WPAN module does not exceed 95% (non-condensing).
Altitude at the installation site is not higher than 10,000 feet.
After replacing or installing a module in the router, you must update the label (on the router exterior) that lists the
module types contained in the router. The label must list the FCC ID number and the IC Certification number for each
module installed in the router. See
Installing the Module
Note: Before you install or remove the CGM-WPAN-OFDM-FCC module within the host router, you must power down
the router as described in either the
Connected Grid Router Hardware Installation Guide.
CAUTION: The module CANNOT be hot swapped. To install the module, you must first power down the module.
Follow these steps to install the module in a supported and available slot in the CGR 1120 or CGR 1240:
1.
Insert the WPAN module into a supported and available slot.
2.
Using a screwdriver, screw both captive screws into place.
Figure 1Front Panel of the CGM-WPAN-OFDM-FCC Module, page 4
Cisco 1120 Connected Grid Router Hardware Installation Guide
6