Electrical Test Instruments PI-2500 & PI-5000
Section II - Detailed Description
==============================================================================
The main electrical power and ground connections to the AUX-5000 are the
same twist-lock connectors as those on the PI-2500. Power cables stored in a
compartment in the AUX-5000 are then connected to the PI-2500. The con-
nectors are color-coded and must be connected with black to black and red to
red.
There is also a control cable which connects from the AUX-5000 to the PI-
2500.
The output of the AUX-5000 is identical to that of the PI-4000B, and accom-
modates standard breaker stabs, for continuous output of 4000 amperes. It
can also be configured in series mode for a continuous output of 2000 am-
peres. The configuration switch on the PI2500 must be set to 4000 or 2000 for
proper output readings.
The combined unit, known as the PI-5000, can only be used on 480 VAC.
==============================================================================