Installing/mounting

3.2 Installation instructions

3.2
Installation instructions
3.2.1

Environment

● Provide easy access for viewing the display and programming via the local push buttons
or the handheld programmer.
● Provide an environment suitable to the housing rating and materials of construction.
1
For more detail, refer to the complete operating instructions.
NOTICE
Damage to the flange
If mating flange faces are not flat and free of distortion, then bolting the flanged process
connection may produce a bending load on the device's flange. Cracking or other damage
may occur.
Use only 'full-face' flat gaskets surrounding the bolt holes. Ensure mating flange faces are
flat and free of distortion.
3.2.2

Nozzle location

Avoid central locations on tall, narrow vessels
Beam angle
● Beam angle is the width of the cone where the energy density is half of the peak energy
density.
● The peak energy density is directly in front of and in line with the antenna.
● There is a signal transmitted outside the beam angle, therefore false targets may be
detected.
18
2
ambient temperature: –40 °C to +80 °C (–40 °F to +176 °F)
process temperature: –40 to +100 °C (–40 to +212 °F) or –40 to +200 °C (–40 to +392 °F) depending
on the version
Compact Operating Instructions, 06/2018, A5E39693895-AA