Table 1 Performance Data (Natural Gas & Propane (P))
Model
Boiler Output
Max
(non-condensing)
Min
Mean 70°C
Boiler Output
Max
(condensing)
Min
Mean 40°C
Nett
Boiler Input
Max Rate
Gross
Nett
Boiler Input
Min Rate
Gross
Gas Rate
Max Rate
Flue Gas Flow Rate
Max Rate
Max Rate
CO
(±0.5%) *
2
Min Rate
DB
NO
(gross)
weighted
x
Seasonal
Efficiency
**SEDBUK 2009
Max. operating temp sealed sys.
Max. operating temp open vented sys.
*CO
measurements taken using controlled reference natural gas. Readings on mains gas quality may vary
2
** The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy ratings of dwellings. The test data from which it has been calculated have
been certified by a notified body.
Table 2 General Data
Model
Gas Supply
Gas Supply Connection
Flow Connection
Return Connection
Max Pressure (sealed sys)
Maximum Static Head
Electricity Supply
Fuse Rating
Power Consumption
IP Rating
Nominal flue dia - Concent.
Condensate Drain
Water Content
Packaged
Unpackaged (dry weight)
Note.
Natural gas consumption is calculated using a calorific value of
37.8MJ/m
(1038Btu/ft
) gross or 34 MJ/m
3
3
15
C and 1013.25 mbar.
o
a. For l/s divide the gross heat input (kW) by the gross C.V. of the
gas (MJ/m
)
3
b. For ft/h
divide the gross heat input (Btu/h) by the gross C.V. of
3
the gas (Btu/ft
).
3
c. For m
/h multiply l/s by 3.6.
3
d. 1kW = 3412 BTU/hr.
e. 1m
= 35.3ft
3
3
f. 1mg/kWh (NOx) = 0.568 ppm DAF (natural gas).
Propane gas consumption is calculated using a calorific value of
95.7 MJ/m
(2500 Btu/ft.
) gross or 88.0 MJ/m
3
3
at 15
C and 1013.25 mbar.
o
To obtain the fuel consumption in liquid form divide the above
figures by 270.
6
SECTION 1 - GENERAL
30
30P
40
kW
30
30
40
kW
6
6
8
kW
31.5
30.9
42
kW
6.5
6.4
8.5
kW
30.4
30.4
40.5
kW
33.7
33
44.9
kW
6.1
6.1
8.1
kW
6.7
6.6
9
3
m
/hr
3.2
1.26
4.3
3
m
/hr
41.3
44.09
54.05
%
9.76
10.9
10.2
%
8.56
10.3
8.6
55.2
55.2
57.7
mg/kWh
34.1
52.3
33.2
%
96.7
97.2
96.2
%
89.6
90.6
89.3
ºC
ºC
30
30P
40
Bar (psi)
m
A
81
W
mm
3.0
L
53.5
Kg
47.5
Kg
(910 Btu/ft
3
3
(2300 Btu/ft.
3
40P
60
60P
40
60
60
8
12
12
41.2
63.5
62.1
8.3
12.7
12.4
40.5
60.8
60.7
44
67.4
66
8.1
12.2
12
8.8
13.5
13.1
1.69
6.4
2.53
61.68
80.65
88.66
11.2
9.4
11.4
9.7
8.6
10.2
57.7
59
59
64.4
35.2
67.7
96.7
96.4
96.9
90.3
89.4
90.5
40P
60
60P
2H – G20 – 20mbar / 3P - G31 - 37mbar
230V - 50Hz
138
82
80/125
5.0
63.5
57.5
HEALTH & SAFETY DOCUMENT NO. 635
The electricity at work regulations, 1989. The manufacturer's
) nett at
notes must NOT be taken, in any way, as overriding statutory
obligations.
IMPORTANT. These appliances are CE certified for safety
and performance. It is, therefore, important that no external
control devices, e.g. flue dampers, economisers etc., are
directly connected to these appliances unless covered by
these Installation and Servicing Instructions or as otherwise
recommended by Ideal Boilers in writing. If in doubt please
enquire.
Any direct connection of a control device not approved by Ideal
Boilers could invalidate the certification and the normal appliance
warranty. It could also infringe the Gas Safety Regulations and
) net
3
the above regulations.
80
80P
100
100P
80
80
100
100
16
16
20
20
84.4
82.6
103.9
101.7
17.2
16.8
21.6
21.3
82
81.9
102.4
102.4
90.9
88.9
113.6
111.2
16.4
16.2
20.5
20.4
18.2
17.5
22.7
22.2
8.7
3.41
10.8
4.35
110.1
121.57
140.5
153.6
9.3
11.4
9.4
10.8
8.7
10.8
8.6
10.1
59.9
59.9
62
62
34.9
63.2
34.8
65.3
97.2
97.7
96.7
96.7
n/a
n/a
n/a
n/a
85
82
80
80P
100
100P
G ¾
G 1¼
G1¼
6.0 (87)
61.0
4.0
149
187
IPX4D
25
120
120P
150
120
120
150
24
24
30
124.7
123.3
158
26
25.7
32.5
122.9
122.9
153.7
136.4
133.4
170.5
24.6
24.5
30.7
27.3
26.7
34.1
13
5.23
16.2
173.33
183.81
210.7
9.62
11.2
9.44
8.98
10.1
8.51
62
62
59
33.9
41.6
35.7
96.6
96.6
96.7
n/a
n/a
n/a
120
120P
150
243
240
100/150
7.0
9.2
80
88
73
81
Installation & Servicing

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents