16. TROUBLESHOOTING
Fault
Fault Description
code
Q axis current
1
detection, step out of
failure
Phase current
2
detection, out of step
Initialization, phase
3
current imbalance
Speed estimation, step
4
out of failure
5
IPM FO output fault
Communication
6
between driver board
and control board fault
AC voltage,overload
7
voltage
DC voltage,overload
8
voltage
9
AC voltage imbalance
The PFC current
detection circuit fault
10
before compressor is
ON
AC voltage supply in
11
outrange
Products of
single-phase PFC
over-current, FO
output low level
12
Inverter over current
(3-phase power supply
air conditioners)
13
Inverter over current
PFC over
current(single-phase
air-conditioner)
Phase imbalance or
14
phase lacks or the
instantaneous power
failure (only for
3-phase power supply
air conditioners)
The instantaneous
15
power failure detection
Sheet 6 Drive Fault Code (36K~60K)
Possible Reason of Abnormality
1. compressor wire connect not well;
2. Bad driver board components;
3. Compressor start load is too large;
4. Compressor demagnetization;
5. Compress or oil shortage serious
wear of crankshaft.;
6. The compressor insulation fault
1.Compressor voltage default phase;
2.Bad driver board components;
3.The compressor insulation fault
Bad driver board components.
1.Bad driver board components;
2.Compressor shaft clamping;
3.The compressor insulation fault.
1. System overload or current
overload.
2. Driver board fault;
3.Compressor oil shortage,serious
wear of crankshaft;
4.The compressor insulation fault.
1.Communication wire connect not
well;
2. Driver board fault;
3. Control board fault;
1. Supply voltage input too high or too
low;
2. Driver board fault;
1. Supply voltage input too high ;
2. Driver board fault;
Driver board fault;
Bad driver board components;
1.Power supply abnormal, power
frequency out of range;
2.Driver board fault;
1. System overload, current too large;
2. Driver board fault;
3. PFC fault.
1. System overload, current too large;
2. Driver board fault;
3. Compressor oil shortage, serious
wear of crankshaft;
4. The compressor insulation fault.
1. System overload, current too large;
2. Driver board fault;
3. Compressor oil shortage,serious
wear of crankshaft;
4.The compressor insulation fault.
1. System overload, current too large;
2. Driver board fault;
3. PFC fault.
1.3-Phase voltage imbalance;
2.The 3-phase power supply phase
lost;
3. Power supply wiring wrong;
4. Driver board fault.
1.The power supply is not stable ;
2.The instantaneous power failure ;
3.Driver board fault;
168
How to Deal With
1. Check compressor wire;
2. Change driver board ;
3. Turn on the machine after pressure
balance again;
4. Change Compressor;
5. Change the Compressor;
6. Change the Compressor.
1.Check compressor wire connection;
2.Change the driver board;
3. Change the Compressor.
Change driver board .
1.Change driver board ;
2.Change the Compressor ;
3.Change the Compressor .
1.Check the air-conditioner system;
2.Change the driver board;
3.Change the Compressor;
4. Change the Compressor.
1. Check compressor wire connect.
2. Change the driver board;
3. Change the control board ;
1.Check power supply;
2.Change the driver board;
1. Check power supply;
2. Change the driver board;
Change the driver board;
Change the driver board
1. Check the system;
2. Change the driver board;
1. Check the system;
2. Change the driver board;
3. Change PFC.
1. Check the system;
2. Change the driver board;
3. Change the Compressor;
4. Change the Compressor.
1. Check the system;
2. Change the driver board;
3. Change the Compressor;
4. Change the Compressor.
1. Check the system;
2. Change the driver board;
3. Change PFC.
1, Check the power supply;
2. Check the power supply;
3. Check the power supply wiring connect;
4.Change the driver board.
1. Check the power supply;
2. Not fault;
3. Change the driver board.