Electrical Specifications

Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.

VOLTAGE

All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
The equipment must be grounded.
A separate fuse/circuit breaker must be provided for
each unit.
Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
RATED AMPERAGES, HORSEPOWER, VOLTAGE & POWER CORD CHART
Display cases come with maximum 8ft (2.4m) cord and plug.
Model
F5MC36DP
F5PC36DP
F5MC48DP
F5PC48DP
F5MC60DP
F5PC60DP
F5MC72DP
F5PC72DP
F15MC48DP
F15PC48DP
F15MC60DP
F15PC60DP
F15MC72DP
F15PC72DP
6
DANGER
Warning
Amps
H.P.
4.5
1/4
5.8
1/3
7.9
1/3
8.1
1/2

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Welbilt does not recommend the use of GFCI/
GFI circuit protection to energize our equipment. If code
requires the use of a GFCI/GFI then you must follow the
local code. The circuit must be dedicated, sized properly
and there must be a panel GFCI/GFI breaker. We do not
recommend the use of GFCI/GFI outlets to energize our
equipment as they are known for more intermittent
nuisance trips than panel breakers.
These appliances will operate within the marked rated
voltage range without adjustment.
This symbol indicates the location of the equipotential
bonding conductor connection.
Volts / Hertz / Phase
Self-Contained Drop-In
115 / 60 / 1
115 / 60 / 1
Self-Contained Serview
115 / 60 / 1
115 / 60 / 1
Section 2

Notice

Notice
Nema Plug
5-15P
5-15P
5-15P
5-15P
Part Number: 9291460 01/20