R
The Evenflo
Automatic Pressure Control prevents initial surging when the gun is triggered,
permitting the operator to maintain a perfectly even spray coating. The control admits air to
the pump as the gun is triggered, and shuts off and exhausts air from the pump as the gun
trigger is released. With the pump's relax-a-valve in the automatic position (see separate
pump instruction manual), the exhausting air opens the relax-a-valve, permitting material to
discharge through the drain back tube until pressure in the hose and pump is relieved.
175 psi (12 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
R
Automatic
306479E
ENG
06412b

Advertisement

loading

Summary of Contents for Graco 202844 Evenflo

  • Page 1 Instructions–Parts List 202844 Evenflo Automatic 306479E Pressure Control The Evenflo Automatic Pressure Control prevents initial surging when the gun is triggered, permitting the operator to maintain a perfectly even spray coating. The control admits air to the pump as the gun is triggered, and shuts off and exhausts air from the pump as the gun trigger is released.
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
  • Page 3 Notes 306479...
  • Page 4 Installation Note: Numbers and letters in parenthesis in the text b. To mount the Evenflo Control directly to a refer to callouts in Fig. 1 and the parts drawing. covered drum, remove the screw (31) and lockwasher (32) from the control (1), and mount it directly to the cover 1.
  • Page 5: Troubleshooting

    Troubleshooting Note: Check all possible solutions before disassem- bling the control. Problem Probable Cause Remedy The Evenflo delivers an insufficient The air supply is insufficient. Check the hose for obstructions or air to the pump when the spray gun leaks. is open.
  • Page 6 Service Daily Maintenance 3. Disassemble the valve; clean the valve thoroughly in a non-flammable solvent, and blow-dry the Relieve the air pressure to the Evenflo , and shut off valve. Inspect all parts for wear or damage. the main valve. Each day, clean the filter screen (10) Inspect the rubber seat (15).
  • Page 7: Parts List

    Parts 20 22 06411b Parts List Ref. Ref. Part No. Description Qty. Part No. Description Qty. 202843 EVENFLO VALVE includes items 2–23 214652 HOSE, air; cpld 3/8 npt(m); 202864 . STEM, by-pass valve 1/2” ID; 18” (457 mm) long 100072 .
  • Page 8 Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.