This appliance may be installed in an aftermar-
ket permanently located, manufactured home
(USA only) or mobile home, where not prohib-
ited by local codes. This appliance is only for
use with the type of gas indicated on the rating
plate. This appliance is not convertible for use
with other gases, unless a certified kit is used.
f i r e - p a r t s . c o m
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WH Report No. J3008600
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION
INSTRUCTIONS
B-VENT
500/600/800 SERIES
B-VENTED GAS APPLIANCES
P/N 700,028M REV. G 11/2004
MODELS
M
l i
v i l
t l o
M
o
e d
B
5 -
0 0
C
M
N
B
5 -
0 0
C
M
P
B
6 -
0 0
C
M
N
B
6 -
0 0
C
M
P
B
8 -
0 0
C
M
N
B
8 -
0 0
C
M
P
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vaperurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appeflez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installer, agence de service ou le fournisseur de gaz.
s l
E
e l
r t c
n o
c i
M
o
e d
B
5 -
0 0
C
E
N
B
5 -
0 0
C
E
P
B
6 -
0 0
C
E
N
B
6 -
0 0
C
E
P
B
8 -
0 0
C
E
N
B
8 -
0 0
C
E
P
s l
1

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products SUPERIOR B-VENT 600 Series

  • Page 1 INSTALLATION INSTRUCTIONS B-VENT 500/600/800 SERIES RETAIN THESE INSTRUCTIONS B-VENTED GAS APPLIANCES FOR FUTURE REFERENCE P/N 700,028M REV. G 11/2004 MODELS This appliance may be installed in an aftermar- ket permanently located, manufactured home v i l t l o r t c (USA only) or mobile home, where not prohib- ited by local codes.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 3 - one hood located behind the top panel. S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instruc- 4 - one bag of decorative volcanic stone located in the control area. tions d'installation et d'utilisation qui Packaging ........
  • Page 3 Millivolt Models - Do not use these appliances if any part has The appliance must be isolated from the gas Millivolt models come standard with the been under water. Immediately call a qualified, supply piping system (by closing its individual manually-modulated gas valve;...
  • Page 4: Location

    In selecting the location, the aesthetic and func- WARNING: CHILDREN AND ADULTS AVERTISSEMENT: POUR UTILISATION tional use of the appliance are primary concerns. SHOULD BE ALERTED TO THE HAZ- UNIQUEMENT AVEC LES PORTES EN However, vent system routing to the exterior and VERRE CERTIFIÊES AVEC L'APPAREIL.
  • Page 5: Fireplace Specifications

    FIREPLACE SPECIFICATIONS FRAMING (Louvered Front Model Shown) SPACERS Flue Outlet For B-Vent Connection (Top and Sides Flue Outlet Shield and Rear) (229) NOTE - Hood shown ELECTRICAL INLET Top View as positioned 2³⁄₄ x 2 (70 x 51) COVER PLATE with KNOCKOUT) in louvered ELECTRICAL INLET front model.
  • Page 6: Framing Specifications

    Step 6. (page 9) Install the optional blower. FRAMING SPECIFICATIONS Back Wall of Chase/Enclosure Including Finishing Materials if any *Optional FOAK Step 7. (page 9) Make connection to gas Outside supply. Air Kit Step 8. (page 10) Outside Air Kit Installa- tion.
  • Page 7 2. Measure the square footage of the floor The fireplace should be secured to the side framing space to be occupied by the system, surrounds members using the unit's nailing flanges - two at the and hearth extensions. top and bottom on each side of the fireplace front. See Figure 11.
  • Page 8: Vent System Installation

    Step 4. Install the Vent System & Exterior Termination - In the United States, vent installation must conform with local building codes. In the absence of local codes, vents must be in- stalled in accordance with the current edition of the National Fuel Gas Code (ANSI-Z223.1). In Canada, vent installation must conform with local building codes.
  • Page 9: Connecting Gas Line

    B. Electronic Wiring (See figure 17 or 18) – Step 6. WIRING - OPTIONAL FORCED AIR Electronic Wiring Diagram (Honeywell) BLOWER KIT Showing the Blower Wiring for the Optional Note: The electronic appliance must be con- FBK-250 Kits nected to the main power supply. FBK-100, FBK-200 and FBK250 Kits 1.
  • Page 10: Outside Air Kit Installation

    Step 8. Outside Air Kits – Optional outside To open the outside air shutter, open the Gas Flex Line Connector make-up air kits, Model FOAK-4 or FAOK-4LD, bottom control access panel, reach into the ³ ₈" NPT x ³ ₈ ¹...
  • Page 11: Installing Logs

    The top ³⁄₈" (10 mm) at the pilot generator Step 11. INSTALLING THE GLASS DOOR Step 9. INSTALLING LOGS, DECORATIVE (thermopile) and the top ¹⁄₈" min (tip) of the quick VOLCANIC STONE AND GLOWING EMBERS drop out thermocouple should be engulfed in the Retrieve the glass door.
  • Page 12: Spillage Test

    Manually-Reset Safety Limit Switch Wire This appliance is equipped with a manually- Termianls reset blocked flue safety limit switch. Refer to Cabinet Figure 28 for its location. If, during appliance Corner operation, the flame goes out (independently of the burner on/off wall switch), it may be Back Of due to the operation of this safety limit switch.
  • Page 13: Finishing Requirements

    MANTEL CLEARANCES Combustible Wall Inches (mm) This Area Must Remain Framing Clear of Combustible 12 (305) MANTEL Materials Combustible Finished Wall 10 (254) MANTEL 1" Min Materials (25 mm) 8 (203) MANTEL Combustible Wall Framing 6 (152) MANTEL Spacer (356) 4 (102) MANTEL Combustible (305)
  • Page 14: Gas Conversion Kits

    GAS CONVERSION KITS AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION WARNING: THIS CONVERSION KIT SHALL BE SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE INSTALLED BY A QUALIFIED SERVICE AGENCY IN CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET ACCORDANCE WITH THE MANUFACTURER'S IN- TOUTES EXIGENCES ET CODES APPLICABLES DE STRUCTIONS AND ALL APPLICABLE CODES AND L'AUTORISÉS AVOIR LA JURIDICTION.
  • Page 15 b. Attach manometer to the manifold side Use a 7/16" open end wrench and turn the pilot d. Push the orifice strip tab all the way against pressure test fitting and verify manifold pres- the hex fitting to align the appropriate gas type hex fitting counter-clockwise 1/4 turn.
  • Page 16 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,028M REV. G 11/2004 1110 West Taft Avenue •...