Safety caution
The terminals Cancel and Alarm1 with contact control, Alarm2, Phone line, connectors for
external LEDs supplied from Lift1, external microphone, external speaker, induction loop, VAS
Alarm, programming connector and the board with electronics are connected to a telephone line
where life-endangering voltage may occur. Connected switches, LEDs and other parts must be
installed with minimum isolation distance 1.5 mm and the minimum breakdown voltage 1500 V.
This applies to the switches itself too!
The DC controlled terminals are separated from the telephone line and do not have to meet the
isolation requirements mentioned above.
Make sure that the cables cannot get in contact with sharp edges during installation to avoid
insulation damage. Check the minimum isolation distance of 1.5 mm after installation using an
isolation meter if possible.
The manufacturer shall not be held liable for any installations made in conflict with these
instructions.
Mounting Drawing for basic model of Lift1
Mounting holes, four M4 spot-
welded screws from shaft side
recomended
Perforated speaker area, in the
cabin wall must be the perforation
for good sound quality, the
perforated area must not exceed
the Lift1 panel
Two optional LED holes, when these
LEDs are used, model with
lightguides is suggested for better
performance
Space for microphone, hole or
perforation in the cabin wall is
necessary
3
EN