Turning Off The Appliance; Complete Shutdown - Honeywell WV8860C Installation Instructions Manual

Water heater controls
Table of Contents

Advertisement

WV8860C WATER HEATER CONTROLS
IMPORTANT
Follow the operating instructions provided by
the manufacturer of your water tank appliance.
The information in this form describes a typical
water heater control application, but the
specific controls used and the procedures
outlined by the manufacturer of your appliance
can differ, requiring special instructions.
STOP: READ THE WARNINGS
ABOVE.
If the appliance does not turn on when the setpoint knob
is set several degrees above the previous temperature,
follow these instructions:
1. Set the temperature setpoint knob to OFF.
2. Turn off the main gas valve to the appliance.
3. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow step 1 in the
warning above. If you DO NOT smell gas, continue
with the next step.
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
www.resideo.com
34-00019—03 M.S. Rev. 01-20 | Printed in United States
©2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
4. Turn on the gas supply to the appliance.
5. Restart the appliance by performing lighting pro-
cedure.
6. Set the setpoint knob to the desired setting.
7. If the appliance does not turn on, turn off the gas
supply to the appliance and contact a qualified
service technician for assistance.

TURNING OFF THE APPLIANCE

Complete Shutdown

1. Turn device knob to OFF. Turn off the gas supply to
the appliance. Appliance will completely shut off.
2. Follow the procedure in the Instructions to the
Homeowner section above to resume normal
operation.