Download Print this page

Turning Off The Appliance - Honeywell TRADELINE VR4304 Manual

Intermittent pilot combination gas control

Advertisement

3. Using an ac voltmeter, check for voltage at the gas
control.
• If pilot lights, measure across MV/PV and MV.
• If pilot does not light, measure across MV/PV
and PV before safety lockout occurs.
4. If voltage is not present, check control circuit for
proper operation.
5. If proper control circuit voltage is present, replace
gas control.
INSTRUCTIONS TO THE HOMEOWNER (FOR
YOUR SAFETY, READ BEFORE OPERATING)
!
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY, OR DEATH
Follow these warnings exactly:
1. Pilot flame is lit automatically. Do not light the
pilot flame manually.
2. Before lighting pilot burner flame, smell around
the appliance for gas. Be sure to smell next to
the floor because LP gas is heavier than air.
3. IF YOU SMELL GAS:
• Turn off the gas supply at the appliance ser-
vice valve. On LP gas systems, turn off gas
supply at the gas tank.
• Do not light any appliances in the house.
• Do not touch electrical switches or use the
phone.
• Leave the building and use a neighbor's
phone to call your gas supplier.
• If you can not reach your gas supplier, call
the fire department.
4. Do not force the gas control knob. Use only
your hand to push down or turn the gas control
knob. Never use any tools. If the gas control
knob will not operate by hand, call a qualified
service technician to replace the gas control.
Force or attempted repair can result in a fire or
explosion.
5. Call a qualified service technician to replace
the gas control if it has been flooded with
water.
6. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
Home and Building Control
Honeywell Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
69-0838
Printed in U.S.A.
Home and Building Control
Honeywell Limited—Honeywell Limitée
740 Ellesmere Road
Scarborough, Ontario
M1P 2V9
8
IMPORTANT: Follow the operating instructions pro-
vided by the manufacturer of your heating appliance.
The information below will be of assistance in a
typical gas control application, but the specific con-
trols used and the procedures outlined by the manu-
facturer or your appliance may differ and require
special instructions.
TO TURN ON THE APPLICANCE
STOP: READ THE WARNINGS ABOVE.
The pilot flame is lit automatically. Do not attempt to
manually light the pilot. If the appliance does not turn on
when the thermostat is set several degrees above room
temperature, follow these instructions:
1. Set the thermostat to its lowest setting to reset the
safety control.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn
clockwise
to OFF.
5. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow step 3 in the Warning in
the Instructions To The Homeowner section. If you do not
smell gas, continue with the next step.
6. Turn the gas control knob counterclockwise
ON.
7. Replace the gas control access panel.
8. Reconnect all electric power to the appliance.
9. Set the thermostat to the desired setting.
10. If the appliance does not turn on, set the gas control
knob to OFF and contact a qualified service technician for
assistance.

TURNING OFF THE APPLIANCE

VACATION SHUTDOWN—Set the thermostat to the
desired room temperature while you are away.
COMPLETE SHUTDOWN—Push in the gas control knob
slightly and turn clockwise
Appliance will completely shut off. Follow the In-
structions to the Homeowner above to resume normal
operation.
to OFF. Do not force.
Helping You Control Your World
QUALITY IS KEY
to

Advertisement

loading