Download Print this page

Device Information; Operating Limits - Dimplex SIK 6TES Installation And Operating Instruction

Brine-to-water heat pump for indoor installation

Advertisement

Available languages

Available languages

SIK 6TES - SIK 14TES

12 Device Information

1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Contr.
2.3
Thermal energy meter
2.4
Installation location
2.5
Performance levels
3

Operating limits

3.1
Heating water flow
3.2
Brine (heat source)
3.3
Antifreeze
3.4
Minimum brine concentration (-13 °C freezing temperature)
4
Flow / sound
4.1
Heating water flow / free compression
Nominal flow in accordance
with EN 14511
Minimum heating water flow
4.2
Brine flow rate / free compression
Nominal flow in accordance
with EN 14511
Minimum brine flow rate
4.3
Sound power level according to EN 12102
4.4
Sound pressure level at a distance of 1m
5
Dimensions, weight and filling quantities
2
5.1
Device dimensions
5.2
Weight of the transportable unit(s) incl. Packaging
5.3
Device connections for heating system
5.4
Device connections for heat source
5.5
Refrigerant / total filling weight
5.6
GWP value / CO
equivalent
2
5.7
Refrigeration circuit hermetically sealed
5.8
Lubricant / total filling quantity
5.9
Volume of heating water in device
5.10 Volume of heat transfer medium in device
6
Electrical connection
6.1
Supply voltage / fuse protection
6.2
Control voltage / fuse protection
6.3
Degree of protection according to EN 60 529
6.4
Starting current with soft starter
www.gdts.one
°C
°C
at B0 / W35...30
m³/h / Pa
at B0 / W45...40
m³/h / Pa
at B0 / W55...47
m³/h / Pa
m³/h / Pa
at B0 / W35...30
m³/h / Pa
at B0 / W45...40
m³/h / Pa
at B0 / W55...47
m³/h / Pa
m³/h / Pa
dB(A)
1
dB(A)
H x W x D mm 1110 x 650 x 655
kg
Inches
Inches
type/kg
--- / t
type/litres
Litres
Litres
A
452231.66.34 · FD 9912
SIK 6TES
SIK 8TES
Brine
Brine
Compact
Compact
Integrated
Integrated
Integrated
Integrated
Indoors
Indoors
1
1
20 to 62 ± 2
20 to 62 ± 2
-5 to 25
-5 to 25
Monoethylene
Monoethylene
glycol
glycol
25 %
25 %
1.0 / 63000
1.4 / 51000
1.0 / 63000
1.3 / 51500
0.6 / 67500
0.8 / 71500
0.6 / 67500
0.8 / 71500
1.4 / 54000
2.1 / 35500
1.3 / 61000
1.7 / 46500
1.1 / 67000
1.5 / 55500
1.1 / 67000
1.5 / 55500
42
42
30
30
1110 x 650 x 655
129
144
R 1¼" external
R 1¼" external
R 1¼" external
R 1¼" external
R410A / 1.2
R410A / 1.6
2088 / 3
2088 / 3
yes
yes
Polyolester (POE) /
Polyolester (POE) /
0.7
1.2
2.8
3.2
2.9
3.4
3~/PE 400 V
3~/PE 400 V
(50 Hz) / C10A
(50 Hz) / C10A
1~/N/PE 230 V
1~/N/PE 230 V
(50 Hz) / C13A
(50 Hz) / C13A
IP 21
IP 21
28 (ohne Sanftan-
18
lasser)
English
SIK 11TES
SIK 14TES
Brine
Brine
Compact
Compact
Integrated
Integrated
Integrated
Integrated
Indoors
Indoors
1
1
20 to 62 ± 2
20 to 62 ± 2
-5 to 25
-5 to 25
Monoethylene
Monoethylene
glycol
glycol
25 %
25 %
1.8 / 33000
2.2 / 18500
1.7 / 35000
2.2 / 18500
1.1 / 63000
1.3 / 51500
1.1 / 63000
1.3 / 51500
2.7 / 78500
3.1 / 63500
2.5 / 84000
3.0 / 65000
2.2 / 95000
2.7 / 81500
2.2 / 95000
2.7 / 81500
43
43
31
31
1110 x 650 x 655
1110 x 650 x 655
147
153
R 1¼" external
R 1¼" external
R 1¼" external
R 1¼" external
R410A / 1.9
R410A / 2.3
2088 / 4
2088 / 5
yes
yes
Polyolester (POE) /
Polyolester (POE) /
1.2
1.2
3.7
4.3
3.9
4.3
3~/PE 400 V
3~/PE 400 V
(50 Hz) / C10A
(50 Hz) / C13A
1~/N/PE 230 V
1~/N/PE 230 V
(50 Hz) / C13A
(50 Hz) / C13A
IP 21
IP21
23
26
EN-11

Advertisement

loading

This manual is also suitable for:

Sik 14tesSik 8tesSik 11tes