Limitless™ WGLA Series
5.2 Battery Connection Procedure
WARNING
RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE
• Connection and disconnection of the batteries should only be performed in a non-hazardous area. The
batteries used in this device may present a risk of fire or chemical burn if mistreated. Do not recharge,
disassemble, heat above 100 °C [212 °F], or incinerate.
Failure to comply with these instructions could result in death or serious injury.
WARNING
RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE
• If WGLA is to be returned to Honeywell for any reason, the battery MUST be removed prior to shipping.
Dispose of used batteries promptly per local regulations or the battery manufacturer's recommendations.
Keep away from children. Do not disassemble and do not dispose of in fire.
Failure to comply with these instructions could result in death or serious injury.
ATTENTION
Use only the following 3.6V lithium thionyl chloride (Li-SOCl2) battery (non-rechargeable), size
2/3AA. No other batteries are approved for use in the WGLA Series limit switch.
•
Uniwell, DEV-10-0009
•
Honeywell, WBT1
WGLA battery activation:
Tools required: Slotted or Phillips screwdriver
Step
Action
1
If applicable, remove the two screws
2
Using a finger, press down slightly on the battery top
battery is properly seated and making good contact.
3
Replace cover and retighten screws or immediately proceed to Section 5.3 Pairing Mode.
Figure 2. Limitless™ Switch Housing
on the housing cover.
and remove the battery insulator
Figure 3. Limitless™ Battery and Insulator
50051863
Issue 2
. Insure that the
Honeywell Sensing and Control 13