Siemens NCU 7x0.3 PN Series Manual page 144

Table of Contents

Advertisement

Connectable components
9.3 PP 72/48D 2/2A PN
Table 9- 64
Measured values and responses in the temperature measurement operating mode
Address
Operating mode
QB72
Format
QB73
Value
QW76
Value
QW78
Operating mode
IB72
Format
IB73
Value
IW76
Value
IW78
Diagnostics
IB50
IB51
PNFault LED
Troubleshooting
144
Incorrect operating mode
16#AA
16#1
-
-
16#AA
16#81
-
-
16#2
16#3
on
Deactivating/activating
Pt100
Resistor is not connected
16#0F
16#1
-
-
16#0F
16#81
-
-
16#2
16#6
on
Deactivating/activating
Manual, 09/2011, 6FC5397-1EP40-0BA0
NCU 7x0.3 PN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncu 710.3 pnNcu 720.3 pnNcu 730.3 pnSinumerik 840d sl

Table of Contents