A.3 Parameter assignment and structure of parameter data record for Oversampling operating mode
Channel header information
The figure below shows the structure of the channel header information.
Figure A-17
Channel parameter block
The figure below shows the structure of the parameters for channels 0 to 7. You enable a
parameter by setting the corresponding bit to "1".
Figure A-18
Digital input module DI 8x24VDC HS (6ES7131-6BF00-0DA0)
Equipment Manual, 11/2019, A5E35243810-AD
Channel header information
Structure byte x to x+1 for the channels 0 to 7
Parameter data records
83