Power requirements IE-CS(T)-2TX-1RS232/485:
Operating temp.
Operating humidity
Dimensions
(W×D×H)
Surge protection
ESD protection
Magnetic isolation
Power line protection 4 KV Burst (EFT), EN61000-4-4
Regulatory approvals CE/FCC Class A, UL 508,
Hazardous Location
Warranty
2
Pull-low resistor
1 K Ω
1)
150 K Ω
12 to 48 VDC, 220 mA@12 VDC; 110
mA@24VDC
IE-CS(T)-2TX-2RS232/485:
12 to 48 VDC, 250 mA@12 VDC; 125
mA@24VDC
0 to 60°C (32 to 140°F) for standard
models
-40 to 75 ºC (-40 to 167 ºF) for extended
temperature models
5 to 95% RH
36 x 105 x 140 mm
1.42 x 41.34 x 55.12 in
1 KV for serial ports
1 KV for LAN ports
15 KV for all signals
1.5 KV for Ethernet
2 KV Surge, EN61000-4-5
UL/cUL Class I, Division 2, Groups A, B, C
and D
ATEX Zone 2: Ex nA nC IIC T3 Gc
5 years