Serial/Ethernet Converter LED Indicators (front panel)
Name
Color
PWR1,
Red
PWR2
Red
Ready
green
orange 10 Mbps Ethernet connection.
green 100 Mbps Ethernet connection.
E1, E2
orange Serial port is receiving data.
green Serial port is transmitting data.
P1, P2

4. Hardware Installation Procedure

STEP 1: After removing the Serial/Ethernet Converter from the box, first
connect the power adaptor. Connect the 12-48 VDC power line
with the terminal block, or connect the DIN-Rail power supply
with the Serial/Ethernet Converter's terminal block.
STEP 2: Connect the Serial/Ethernet Converter to a network. Use a
standard straight-through Ethernet cable to connect to a Hub
or Switch. When setting up or testing the Serial/Ethernet
Converter, you might find it convenient to connect directly to
your computer's Ethernet port. Use a cross-over Ethernet
cable If the PC don't support autocrossing.
STEP 3: Connect the Serial/Ethernet Converter's serial port to a serial
device.
STEP 4: The Serial/Ethernet Converter is designed to be attached to a
DIN-Rail or mounted on a wall. For DIN-Rail mounting, push
down the spring and properly attach it to the DIN-Rail until it
"snaps" into place. For wall mounting, install a wall mount kit
first, and then screw the device onto the wall. The following
figure illustrates the two mounting options:
Power is being supplied to power input PWR1
or PWR2
Steady on: Power is on and the
Blinking:
Steady on: Power is on and the
Blinking:
off
Power is off, or a power error condition exists.
Ethernet cable is disconnected, or has a
off
short.
No data is being transmitted or received
off
through the serial port.
Function
Serial/Ethernet Converter is
booting up.
Indicates an IP conflict, the
DHCP or BOOTP server did not
respond properly, or a relay
output occurred.
Serial/Ethernet Converter is
functioning normally.
The Serial/Ethernet Converter
has been located by the
Administrator's "Locate" function.