1. Certificate number DEMKO 13 ATEX 1207259X
2. Ambient range (-40°C ≤ Tamb ≤ 75°C)
3. Certification string (Ex nA nC IIC T3 Gc)
4. Standards covered (EN 60079-0:2012+A11:2013, EN 60079-15:2010)
5. The conditions of safe usage:
The Ethernet Communication Devices are to be mounted in an IP54
enclosure and used in an area of not more than pollution degree 2 as
defined by IEC60664-1.
A 4 mm² conductor must be used when connection to the external
grounding screw is utilized
Conductors suitable for use in an ambient temperature greater than
91°C must be used for the power supply terminal.
Provisions shall be made, either in or external to the apparatus, to
prevent the rated voltage from being exceeded by more than 40% due
to transients disturbances.
7. Pull-high, Pull-low, and Terminator for RS-485
Remove the Serial/Ethernet Converter's top cover and you will find DIP
switches to adjust each serial port's pull-high, pull-low, and terminator.
IE-CS(T)-2TX-1RS232/485
ATEX Information
IE-CS(T)-2TX-2RS232/485
- 7 -