  • Page 3: Foreword

    Foreword Foreword Revision history Version Date Change 04/08 First edition 08/10 WAVE TTA EX products complemented and edito- rial changes Contact address Weidmüller Interface GmbH & Co. KG Postfach 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Germany Phone +49 (0) 5231 14-0...
  • Page 4: Table Of Contents

    Contents Contents F oreword ..........................1 H 1 H 1 H 8 2 H 8 2 H 8 2 H R evision history..............................2 H 2 H 2 H 8 3 H 8 3 H 8 3 H C ontact address..............................3 H 3 H 3 H 8 4 H 8 4 H 8 4 H C ontents ..........................
  • Page 5: Contents

    Contents Setup / Configuration..................3 0 H 3 0 H 3 0 H 1 1 1 H 1 1 1 H 1 1 1 H 7 .1 Default setting ..........................3 1 H 3 1 H 3 1 H 1 1 2 H 1 1 2 H 1 1 2 H 7 .2 CBX100 USB and CBX200 USB introduction ................
  • Page 6 Contents 5662300000/01/08.10...
  • Page 7: Approvals

    Approvals Approvals CE................................ 1 3 1 H 1 3 1 H 1 3 1 H UL................................ 1 3 2 H 1 3 2 H 1 3 2 H GL................................ 1 3 3 H 1 3 3 H 1 3 3 H ATEX..............................
  • Page 8: Atex

    Approvals CE Declaration is available from Weidmüller. Listing approval cULus Germanischer Lloyd approval for products: 8939670000 and 8939680000 ATEX Approval according ATEX directive EN 60079-0 and EN 60079-15 for NON Sparking for products: 8964310000 und 8964320000 Class 1 Division 2 Approval according C1D2 Zone 2: ISA121201 for products: 8964310000 und 8964320000 5662300000/01/08.10...
  • Page 9: Warrantee Statement

    Warrantee statement Warrantee statement 36 months warranty ........................1 3 6 H 1 3 6 H 1 3 6 H 5662300000/01/08.10...
  • Page 10: 36 Months Warranty

    Warrantee statement 36 months warranty Weidmüller gives a 36 months warranty on the WAVE TTA product in accordance with the warranty terms as described in the general conditions of sale of the Weidmüller company which has sold the products to you.
  • Page 11: Notes On Safety

    Notes on Safety Notes on Safety Electrical precautions ........................1 3 7 H 1 3 7 H 1 3 7 H Handling ............................1 3 8 H 1 3 8 H 1 3 8 H 5662300000/01/08.10...
  • Page 12: Electrical Precautions

    Notes on Safety Electrical precautions DANGER! This product may be connected to po- tentially lethal voltages! DANGER! The configuration plug jack must only be used for configuration in non- hazardous areas! WARNING! • Before you remove or mount the unit, turn-off the power supplies –...
  • Page 13: Introduction

    Introduction Introduction Symbol identification ........................1 4 2 H 1 4 2 H 1 4 2 H Types / article numbers ........................1 4 3 H 1 4 3 H 1 4 3 H General description / applications / examples................1 4 4 H 1 4 4 H 1 4 4 H 5662300000/01/08.10...
  • Page 14: Symbol Identification

    (CBX100 USB or CBX200 USB) interface and (TTA Set) software. The CE mark proves the compliance of The WAVE TTA can be powered from DC or AC the product with the requirements of the sources between 18 and 264 volts.
  • Page 15 Introduction • Selectable output value for a thermocouple-break Typical Applications event. Typical of applications for the WAVE TTA is the • Flashing LED status indicator on the unit front on conversion of thermocouple temperature input (low thermocouple-break. range of millivolts) into a high level (e.g. 4-20 mA) •...
  • Page 16 Introduction 5662300000/01/08.10...
  • Page 17: Operation

    Operation Operation Status & alarm LEDs ........................1 4 5 H 1 4 5 H 1 4 5 H Functional block diagram....................... 1 4 6 H 1 4 6 H 1 4 6 H Specifications ..........................1 4 7 H 1 4 7 H 1 4 7 H 5662300000/01/08.10...
  • Page 18: Status & Alarm Leds

    Operation Status & alarm LEDs Analogue Output status with alarm • User may select output value under fault condi- Status LED tions Under normal conditions this (green) LED is on con- • Output compliant with NAMUR recommendations tinuously. (NE43) can be set (< 3.6 mA or > 21 mA) Input fault detection Input faults such as short circuit or open circuit can be detected for most input types.
  • Page 19: Functional Block Diagram

    Operation Functional block diagram Figure 4 Functional block diagram 5662300000/01/08.10...
  • Page 20: Specifications

    Operation Specifications Input types Thermocouple Range -200...+1820 °C Types B, E, J, K , L, N, R, S, T to IEC 60584 plus custom specific 2, 3, 4 wire, within the range -200...+850 °C, for Pt100, Pt1000 to IEC 60571 and for Ni100 / Ni1000 to DIN 43760, for Cu10 and,100 plus custom specific Potentiometer 10 Ω...100 kΩ...
  • Page 21 UL 94 V0 Housing colour Black Ingress protection IP20 Approvals WAVE TTA CE, cULus, GL Approvals WAVE TTA EX CE, cULus, Class 1 Division 2 / Zone 2, ATEX Zone 2 Type Order No. WAS6 TTA 8939670000 (screw connectors) WAZ6 TTA...
  • Page 22 Operation 5662300000/01/08.10...
  • Page 23 Installation Installation General (Competence Warning) ....................1 4 8 H 1 4 8 H 1 4 8 H Mounting / Environmental / EMI protection / warm up ..............1 4 9 H 1 4 9 H 1 4 9 H Marking.............................
  • Page 24: Installation

    Do not install input, output and power supply cables Mounting close to sources of electrical interference. For ex- WAVE TTA is designed to be mounted onto a TS35 ample, such sources could include relays, contac- DIN rail. tors, motors and their controls, including thyristor It clips onto the rail via a spring-loaded mounting drives, and the cables which connect these devices.
  • Page 25: Marking

    Test terminals are included to permit input and out- put currents to be monitored without disconnection of cables (see connection diagram below). WARNING! WAVE TTA and PC have to be fully de- energized, before the programming in- terfaces CBX100 USB or CBX200 USB will be connected.
  • Page 26: Connection Diagram

    Installation Connection diagram The connection diagram below is printed on the side of the WAVE TTA housing. Connection diagram – Power supply Term. No. 24 - 240 V DC / AC Table 4 Power supply Connection diagram – Input Resistor / RTD Term.
  • Page 27 Installation Connection diagram – Analogue output Term. No. 0…20 mA 0…10 V -10 V…+10 V Out+ / TP- Out- Out- Out+ Out+ Out- Table 6 Analogue output Connection diagram – Digital output relay Term. No. Alarm 1 Alarm 2 Table 7 Digital output 5662300000/01/08.10...
  • Page 28 Installation 5662300000/01/08.10...
  • Page 29: Setup / Configuration

    Setup / Configuration Setup / Configuration Default setting ..........................1 5 3 H 1 5 3 H 1 5 3 H CBX100 USB and CBX200 USB introduction ................1 5 4 H 1 5 4 H 1 5 4 H Configuration / diagram wiring ......................
  • Page 30: Default Setting

    USB introduction The CBX100 USB or CBX200 USB is the configura- 4-20 mA Input range tion interface for the WAVE TTA. This is the same ADS Speed medium interface as can be used for configuring the ITX Plus universal transmitter.
  • Page 31: Tta Set Software

    TTA Set software TTA Set software Description............................1 5 6 H 1 5 6 H 1 5 6 H Installation ............................1 5 7 H 1 5 7 H 1 5 7 H Starting/exiting TTA Set ......................... 1 5 8 H 1 5 8 H 1 5 8 H Title bar ............................
  • Page 32: Description

    The Windows based TTA Set software is configura- File tion software to set up the universal analogue condi- Change the setting to default set- tioning module WAVE TTA via the interface tings. CBX100 USB or CBX200 USB. Open Open a configuration file *.tta from the hard disk.
  • Page 33 TTA Set software Info Settings Temperature unit Set the unit of the temperature About Open an information window for the configuration. Celsius or about the software version and Fahrenheit the contact address of Weid- müller. Figure 10 Titlel bar - Settings - Temperature unit Setpoint / Settings from the unit (percent Running Values...
  • Page 34: Overview Parameters

    TTA Set software Overview parameters Input parameters Type of Voltage - Range V: -20 … +50 V DC input Min. Span 0.5 V mV: -200 … +500 mV DC Min. Span: 4 mV Current - Range Passive Range mA: -20 … +50 mA Min.
  • Page 35 TTA Set software Transfer parameters Transfer Transfer function for the output signal: function Function linear SQRT X^1.5 X^2.5 formula Out = In Out = In Out = In Out = In Out = In x 10 x 0.1 0.01 0.001 Input Output Output...
  • Page 36 TTA Set software Figure 14 User-defined transfer function ADC Speed Fast Highest sampling rate 9.5 ms Medium 50 - 60 Hz 60 ms Slow 50 - 60 Hz 180 ms Response Response time is the time between an input step and the output step. Time Response Voltage /...
  • Page 37 Output – for error Output @ Error Output @ Error condition If an input or WAVE TTA error oc- If an input or WAVE TTA error oc- curs the output is set to this value. curs the output is set to this value.
  • Page 38 = setpoint ± window value e.g.: setpoint 40%, window 10% = window value is from 30-50%. Input Error If an input or WAVE TTA error occurs the output is set to this value. The alarm relay is activated after power on. Function cir-...
  • Page 39 TTA Set software Error Action Alarm ON The alarm relay is activated when an error is detected. Alarm OFF The alarm relay is deactivated when an error is detected. Hold The alarm relay hold the actually status. None No reaction on an error. Table 9 Parameter High Alarm...
  • Page 40 TTA Set software Alarm Time Delay Figure 18 Alarm Time Delay In this example the time delay is set for 20 seconds. At t the measurement exceeds the alarm value, but this only lasts for 10 seconds so there is no trip. At t the measurement again exceeds the alarm trip value and this lasts for longer than 20 seconds so the alarm trip occurs after 20 seconds.
  • Page 41: Run Mode

    Enter your password (the default password is ured the module. 0000). To reset a personal password, send a re- quest with the serial number of the WAVE TTA to Initials: Initials or the name of the the following e-mail address: person who last config- password.tta@weidmueller.com...
  • Page 42: Updates

    TTA Set software Figure 19 Unit-ID A Terminals Updates Downloading the latest version The latest version of the TTA Set Software is available from the Weidmüller website at www.weidmueller.com. 5662300000/01/08.10...
  • Page 43: Testing The Product

    Testing the product Testing the product Test procedure ..........................1 6 4 H 1 6 4 H 1 6 4 H 5662300000/01/08.10...
  • Page 44: Test Procedure

    Depending on the measurement accuracy required from the WAVE TTA, the input signal source and output meter errors should sum to typically better than 1/3 of the accuracy required. Mount the WAVE TTA with the power supply on a DIN rail and consider the following connection diagram in chapter 1 6 6 H 1 6 6 H 1 6 6 H Connect the input sensor e.g.
  • Page 45 Testing the product Figure 20 Screenshot TTA Select the input signal type e.g. "Potentiometer" and set the input values "Input Low" and "Input High". Select and set the output signal type required ("Current" or "Voltage"). Select and set the digital outputs as required. Click the button "Send to Instrument".
  • Page 46 Testing the product 5662300000/01/08.10...
  • Page 47: 0. Troubleshooting

    Troubleshooting 10. Troubleshooting 10.1 Troubleshooting ..........................1 6 8 H 1 6 8 H 1 6 8 H 5662300000/01/08.10...
  • Page 48 10.1 Troubleshooting The green Status LED is flashing If a WAVE TTA is not working as expected, the best It indicates sensor wiring (short circuit or open cir- view of its complete set-up is via the configuration cuit) or internal fault.
  • Page 49: Appendix

    Appendix Appendix Appendix A: Article Overview ........................1 7 4 H 1 7 4 H 1 7 4 H Index ................................1 7 5 H 1 7 5 H 1 7 5 H 5662300000/01/08.10...
  • Page 50: Appendix A: Article Overview

    Appendix Appendix A: Article Overview Modules WAVE TTA WAS6 TTA 8939670000 WAZ6 TTA 8939680000 WAS6 TTA EX 8964310000 WAZ6 TTA EX 8964320000 USB Interface CBX100 USB 7940025031 CBX200 USB 8978580000 Accessory WS 15/5 MC NEUTRAL PU 480 1609880000 Table 11 Article overview 5662300000/01/08.10...
  • Page 51: Index

    Appendix Index Figure Page F igure 1 Handling 5 0 H 5 0 H 5 0 H 1 7 6 H 1 7 6 H 1 7 6 H F igure 2 Installation overview 5 1 H 5 1 H 5 1 H 1 7 7 H 1 7 7 H 1 7 7 H F igure 3 LEDs...
  • Page 52 Appendix Table Page T able 1 Status indicators 7 1 H 7 1 H 7 1 H 1 9 7 H 1 9 7 H 1 9 7 H T able 2 Input fault detection 7 2 H 7 2 H 7 2 H 1 9 8 H 1 9 8 H 1 9 8 H T able 3 Specifications...
  • Page 54 www.weidmueller.com Weidmüller Interface GmbH & Co. KG Postfach 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Germany Phone +49 (0) 5231 14-0 +49 (0) 5231 14-2083 E-Mail info@weidmueller.com 5 662300000/01/08.10 Internet www.weidmueller.com 1 6 5 H 2 8 1 H 2 8 1 H 2 0 3 H 2 0 8 H 2 0 8 H 2 0 8 H...