AQUALUX Dynamic 103648 Installation And Care Instructions page 31

Salt chlorinator
Table of Contents

Advertisement

Available languages

Available languages

Possible causes
Low salt rate in the water (not enough salt added
initially, heavy rain, leak in the pool)
Wrong calibration of the salinity controller.
The salinity controller cannot be calibrated.
Possible causes
The power cable of the cell is not correctly connected
Cell clogged by debris.
Defective cell.
Defective elecronic card.
Possible causes
Water temperature is too low (<15°C).
The temperature sensor is disconnected
(The system idicates a temperature of 75°C)
The temperatre displayed is not the actual water
temperature.
The sensor cannot be calibrated.
Possible causes
There is no water in the cell/
Presence of air or gas in the cell
Defective salinity detector
Possible causes
The cell's power cable is wrongly connected.
Damaged power cable.
Scale formation
NOTESD - IND B – 02/2012
Low salt alarm
Test the salinity. Add some more salt as indicated above.
Proceed with the calibration.
Replace the salinity controller.
Short circuit alarm
Corrective actions
Check the cable connections on the cell and the unit.
Remove the cell for inspection.
Refer to the cell cleaning procedure.
Contact your retailer.
Contact your retailer.
Low temperature alarm
Corrective actions
Winter your swimming pool.
Connect the temperature sensor.
Calibrate the sensor.
Replace the sensor.
Lack of water alarm
Corrective actions
Check the by-pass valves' position.
Drain the cirucit and modify the position of the cell on the
installation if necessary. (see fugures 6.1.1 and 6.1.2)
Replace the salinity detector.
Open circuit alarm
Corrective actions
Redo the connections.
Replace the cable.
Clean the cell with vinegar
31 / 52
Corrective actions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynamic 103649

Table of Contents