Maintenance and Repair
Overhead Supply Adapter (Oil Reservoir
Models)
Refer to F
. 18 for reference numbers used in the fol-
IG
lowing instructions.
The Overhead Supply Adapter replaces the standard oil
reservoir and allows the oil to be directly fed to the pump
through a hole in the reservoir cap.
Disassembly
The disassembly procedure may be performed with the
adapter mounted on the pump. However, some mount-
ing locations may be too restrictive to provide access to
all components.
If installation requires dismounting of the adapter, drain
the adapter of lubricant before removing the attaching
hardware. This reduces the weight of the adapter and
reduces the chance of spillage.
1. Shut off the lubricant supply to the overhead supply
adapter and drain the oil from the reservoir. Follow
Prepare for Maintenance, on page 16, for reservoir
draining instructions. Properly dispose of emptied oil
adhering to all applicable safety regulations and
municipality codes.
2. Remove the three nuts (201) and lock washers
(204) from screws (203).
3. Remove the screws from the reservoir cap (209).
4. Remove the reservoir cover (209) from the adapter
tube (210).
5. Remove the adapter tube (210) from pump.
6. Remove and discard the gaskets (205 and 206).
22
F
. 18:
IG
Reassembly
1. Install the lower gasket (206) on the pump body.
2. Install the adapter tube (210) on the gasket (206).
3. Install the reservoir gasket (205) on top of the
adapter tube (210).
4. Install the reservoir cap (209) on the reservoir gas-
ket (205).
5. Rotate the reservoir cover (209) until the screws
(203) can be installed through the holes in the cap
and the pump. The heads of the screws (203) must
fit into the hexagonal depressions on the upper sur-
face of the reservoir cover (209).
6. Install the lock washers (204) and nuts (201) on the
screws (203).
7. Torque the nuts to 5 ft-lbs (6.78 N•m).
NOTE: After reassembly, any components removed to
ease disassembly should be reinstalled on the adapter.
203
209
204
201
205
210
206
3A2781B