Factory Reset; Resetting The Connectstation Via Admin Interface; Resetting The Connectstation Via Usb Keyboard; Resetting The Access Point - Sennheiser MobileConnect User Documentation

Hide thumbs Also See for MobileConnect:
Table of Contents

Advertisement

Factory reset

Resetting the ConnectStation via Admin Interface

To reset the ConnectStation to factory settings:
Connect your computer to LAN3 of the ConnectStation.
Open a browser and navigate to 192.168.0.10.
Login with your user credentials.
In the Update & Reset tab click on Perform reset now.
The ConnectStation will be reset to factory settings.

Resetting the ConnectStation via USB keyboard

To reset the ConnectStation via USB keyboard:
Connect the access point to the ConnectStation.
Power up both the ConnectStation and the access point.
Wait until the system is ready (2-3 min).
Connect a USB keyboard to one of the USB sockets of the ConnectSta-
tion.
Type reset and press Enter.
The ConnectStation and the access point will be reset to factory set-
tings.
Log into the admin interface with the default login details:
• Username:
admin
• Password:
sennheiser
If the admin interface shows that the access point is not getting
connected, a hard reset of the access point has to be performed. See
below: "Resetting the access point").

Resetting the access point

To reset the access point Ruckus ZoneFlex 7372 to factory settings:
Disconnect the access point from its power supply.
Press and hold the RST (reset) button of the access point.
Insert the power supply into the access point while holding the RST
button.
Hold the RST button for approximately 15 seconds.
The access point will be reset to factory settings.
Factory reset
78

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents