  • Page 1 MANUALE ISTRUZIONI D'USO Aerosol elettronico portatile INSTRUCTIONS FOR USE MANUAL Portable electronic nebulizer...
  • Page 2 Destinazione d’uso: Questo Dispositivo Medico è un apparecchio per aerosol- terapia elettronico con tecnologia PMVT (Passive MESH Vibrating Technology). Smarty è adatto a nebulizzare farmaci in soluzione (mucolitici in genere), far- maci in sospensione (p.es. corticosteroidi, come beclometasone dipropiona- to e budesonide) e soluzione fisiologica.
  • Page 3 INDICE DEI COMPONENTI DELL’APPARECCHIO 1 - Corpo Apparecchio 1A - Tasto nebulizzazione A RICHIESTA 1B - Tasto nebulizzazione CONTINUA 1C - Pulsante di Sgancio Posteriore 1D - Sportello Vano Batterie 1E - Vano Batterie 2 - Camera farmaco completa estraibile 2A - Serbatoio farmaco 2B - Parte Anteriore 2C - Gancio Coperchio Serbatoio...
  • Page 4: Avvertenze Importanti

    AVVERTENZE IMPORTANTI Smarty richiede alcune precauzioni. stare la massima attenzione quando è utilizzato da bambini. sufficienti, è necessaria la stretta supervisione di un adulto che abbia letto il presente manuale. ter essere inghiottite dai bambini; conservate quindi l’apparecchio fuori dalla portata dei bambini.
  • Page 5: Inserimento Delle Batterie

    Prima di ogni utilizzo, il nebulizzatore e gli tati come indicato nel paragrafo 6. PULI- ZIA, SANIFICAZIONE, DISINFEZIONE. Si consiglia l’uso personale sia del nebuliz- zatore, sia degli accessori per evitare even- media prevista degli accessori è di circa un anno. Utilizzate solo accessori originali Flaem.
  • Page 6: Configurazione Dell'apparecchio

    procedere alla preparazione della terapia inalatoria. 2.1 Sollevate il Gancio (2C) del Coperchio (2D) 2.2 Aprite completamente il Coperchio (2D) 2.3 Versate il farmaco (MAX 8 ml) nel Ser- batoio (2A) 2.4 Richiudete il Coperchio (2D) 2.5 Bloccate il Gancio del coperchio (2C) ATTENZIONE! Dopo aver versato il farmaco nel Serbatoio (2A), NON premete i Pulsanti Serbatoio...
  • Page 7: Funzionamento

    4 - FUNZIONAMENTO Con Smarty è possibile scegliere fra le seguenti due modalità di erogazione: “A RICHIESTA” e “CONTI- NUA”. 4.1 Tasto (1A) Premete questo tasto nella sola fase inspiratoria per ottenere l’erogazione del far- maco in modalità “A RICHIESTA”; l’apparecchio funziona solo se mantenete premuto il tasto.
  • Page 8: Smontaggio Dell'apparecchio

    5 - SMONTAGGIO DELL’APPARECCHIO Terminata l’applicazione terapeutica, procedete come segue: 5.1 Premete il Pulsante di Sgancio (1C) posto sul retro dell’apparecchio. 5.2 Sfilate la Camera farmaco completa estraibile (2) 5.3 Procedete alla completa pulizia come illustrato nel capitolo 6. PULIZIA, SA- NIFICAZIONE, DISINFEZIONE.
  • Page 9 ATTENZIONE! Testina di nebulizzazione (2G). Testina di nebulizzazione (2G) con le dita o con degli utensili, potreste danneggiarla irreparabilmente.
  • Page 10 6 - PULIZIA, SANIFICAZIONE, DISINFEZIONE Prima e dopo ogni utilizzo, l’apparecchio e gli accessori devono essere puli- ti e disinfettati correttamente come di seguito descritto. Se ciò non avvenis- se, alcuni microrganismi potrebbero depositarsi nell’apparecchio, causan- do il rischio d’infezione. Non utilizzate alcool per la pulizia del dispositivo. 6.1.
  • Page 11 6.2 PULIZIA Corpo Apparecchio Utilizzate una spugna morbida o un panno leggermente inumiditi con detergente antibatterico per la pulizia del Corpo Apparecchio (1). Asciugatelo poi con un tovaglio- lo di carta morbida. ATTENZIONE! Non immergete il Corpo Apparecchio (1) in ac- qua e non lavatelo sotto il getto d’acqua del ru- binetto.
  • Page 12 a contenere tutti i singoli accessori da disinfettare con una soluzione a base di acqua potabile e di disinfettante, rispettando le proporzioni indicate sulla confezione del disinfettante stesso. 6.4.2. Immergete completamente ogni singolo accessorio nella soluzione, avendo cura di evi- tare la formazione di bolle d’aria a contatto con periodo di tempo indicato sulla confezione del di- sinfettante, e associato alla concentrazione scelta...
  • Page 13 7.3. Chiudete la Camera farmaco completa estraibile (2) ruotando il Serbatoio Farmaco (2A) verso la Parte Anteriore (2B) fino all’aggancio dei due Pulsanti Ser- batoio (2E). 7.4. Chiudete il Coperchio Serbatoio (2D) e bloccatelo con il Gancio Coperchio Serbatoio (2C). 7.5.
  • Page 14: Localizzazione Dei Guasti

    Serbatoio (2D) non sia ostruito, nel caso pulitelo con un ago. Se dopo aver verificato le condizioni sopradescritte, l’apparecchio non dovesse ancora nebulizzare, con- sigliamo di rivolgervi al vostro rivenditore di fiducia o presso un centro di assistenza autorizzato Flaem.
  • Page 15: Caratteristiche Tecniche

    8 - CARATTERISTICHE TECNICHE Nebulizzatore Elettronico Smarty Modello P0309EM Alimentazione AA Alcaline da 1,5Vdc 2,4Vdc con 2 Batterie stilo Potenza 1,5W Frequenza del trasduttore Rumorosità Dimensioni apparecchio Peso nebulizzatore (batterie escluse) 125g Dimensioni borsello Erogazione ml/min MMAD 3,17 μm Frazione respirabile <5μm Capacità...
  • Page 16: Smaltimento Dell'apparecchio

    RF (telefoni cellulari o connessioni wireless) potrebbero interferire con il funzionamento dei dispositivi elettromedicali. Per ulteriori informazioni visita- te il sito internet www.flaem.it . Flaem si riserva il diritto di apportare modifiche tecniche e funzionali al prodotto senza alcun preavviso.
  • Page 17 RICAMBI E ACCESSORI DISPONIBILI Boccaglio (in silicone) ACO563P Mascherina Pediatrica (Soft-touch silver) ACO438P Mascherina Adulto (Soft-touch silver) ACO437P Testina di nebulizzazione ACO562P Camera farmaco completa ACO567P...
  • Page 18 Thank you for your purchase. Our goal is the complete satisfaction of our customers by offering cutting-edge products for the prevention and treatment of the respiratory tract ailments. Visit our website www.flaem.it to view the wole range of Flaem’s products. Read these instructions carefully in order to use the device correctly.
  • Page 19 LIST OF DEVICE COMPONENTS 1 - Main Unit 1A - ON DEMAND nebulisation button 1C - Medication chamber release button 1D - Battery Compartment Cover 1E - Battery Compartment 2 - Removable medication chamber 2A - Medicine cup 2B - Nebulising chamber 2C - Medication cup locking clip 2D - Medication cup cover 2E - Nebulising chamber and...
  • Page 20: Important Warnings

    IMPORTANT WARNINGS Smarty requires some basic safety precautions. used by children. special assistance, the supervision of an adult who has read this manual is necessary. the device out of reach of children. Rechargeable batteries shall be charged using a battery charging device that is not supplied with this device.
  • Page 21: Battery Installation

    CLEANING, SANITISA- TION, DISINFECTION instructions (para- graph 6) We recommend personal use, both of the nebuliser and accessories to avoid possible risk of infection. The average life span of the accessories is approximately 1 year. Use only FLAEM original accessories.
  • Page 22: Unit Configuration

    Wash your hands thoroughly before preparing the medication locking clip (2C) of the Medication cup cover (2D) 2.2 Open the Medication cup cover (2D) completely 2.3 Pour the medicine (MAX 8 ml) into the Medication cup (2A) 2.4 Close the Medication cup cover (2D) 2.5 Fasten the locking clip (2C) WARNING! After pouring the medicine into the...
  • Page 23: Operation

    4 - OPERATION Select the preferred delivery mode (“ON DEMAND” or “CONTINUOUS”) 4.1 ON DEMAND button (1A) Press this button when inhaling to obtain the delivery of medi- cation “ON DEMAND”. The device works only when you press the button. 4.2 START AND STOP / CONTINUOUS button (1B): Press this button to obtain the “CONTINUOUS”...
  • Page 24 5 - DISASSEMBLY When treatment is finished: 5.1 Press the Medication chamber release button (1C) positioned on the back of the unit. 5.2 Remove the Medication chamber (2). 5.3 Carefully clean it according to the CLEANING, SANITISATION, DISINFECTION instructions in paragraph 6. 5.4 To access the Nebuliser head (2G) in the Nebulising chamber(2B) release the Medication cup locking clip and open the Medication cup cover (2D).
  • Page 25 WARNING! Nebuliser head (2G). Nebuliser head (2G) with your fingers or tools from the inside: this may cause irreparable damage.
  • Page 26 6 - CLEANING, SANITISATION, DISINFECTION Before and after each use, the device and the accessories must be cleaned and disinfected properly as described below. If this is not done, some mi- croorganisms may collect in the device, causing the risk of infection. Abso- lutely do not use alcohol to clean the device 6.1.
  • Page 27 6.2 CLEANING the Main Unit To clean the Main Unit(1) use a soft sponge or a cloth slightly moistened with an antibacterial detergent, then dry it with a soft paper towel. ATTENZIONE! Do not immerse the Main Unit (1) in water and do not wash it under running water.
  • Page 28 disinfection according to the dilution proportions recommended in the disinfectant instructions. 6.4.2. Submerge every component completely in the solution; try to prevent that air bubbles form ponents immersed for the period recommended on the disinfectant instructions based on the se- 6.4.3.
  • Page 29 7.3. Close the Removable Medication chamber (2) by rotating the Medication Cup (2A) towards the Nebulising chamber (2B) until the two clips (2E) are locked. 7.4. Close the Medication Cup Cover (2D) by means of the locking clip (2C) 7.5. Insert the Removable Medication chamber (2) onto the Main Unit (1) matching the guides on the two parts.
  • Page 30: Troubleshooting

    Medication cup cover (2D) is not obstructed. If so clean it with a needle If after checking the aforementioned conditions, the unit still does not nebulise, we recom- mend that you contact the dealer or an authorised Flaem service centre.
  • Page 31: Technical Characteristics

    8 - TECHNICAL CHARACTERISTICS Smarty Electronic Nebuliser Model P0309EM Power Supply AA Alkaline, 1.5Vdc 2.4Vdc with 2 Batteries Power 1.5W Transducer frequency Noise level Device dimensions Device weight (excluding batteries) 125g Carry bag dimensions Delivery rate ml/min MMAD 3.17 μm Breathable fraction <5μm...
  • Page 32: Disposal Of Device

    Radio and mobile telecommunications devices or portable RF (mobile phones or wireless connections) may interfere with the operation of electrical medical devices. For further information visit www.flaem.it website. Flaem reserves the right to make technical and functional modifications to the product without notice. 14 - DURATA PREVISTA...
  • Page 33: Available Spare Parts And Accessories

    AVAILABLE SPARE PARTS AND ACCESSORIES Mouthpiece (made of silicone) ACO563P Child mask (Soft-touch silver) ACO438P Adult mask (Soft-touch silver) ACO437P Nebuliser head ACO562P Removable Medication Chamber ACO567P...
  • Page 36: Certificato Di Garanzia

    CERTIFICATO DI GARANZIA Condizioni di Garanzia: L’APPARECCHIO SMARTY E’ GARANTITO 2 ANNI DALLA DATA DI ACQUISTO componenti con vizi di fabbricazione. Sono esclusi dalla presente garanzia le parti soggette a naturale usura, i danni derivati da usi impropri, da cadute, dal trasporto, dalla mancata manutenzione o comunque da cause non attribuibili al costruttore.