Additional Controller(s)
When measuring resistance always make sure the power supply to the unit is turned off and the
component being check is isolated from the P.C. board
1. Measure voltage of Additional Remote Controller(s) on the P.C. board at Connector CN211:
a. Connector "CN211" on the P.C. board check across terminals 1 & 3 for 10 ~ 13 VDC.
© 2015 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
Note: The activation flow rate for the N-Series Water Heaters is 0.4 gpm.
No need to make any adjustments when set above 120 degrees Fahrenheit.
Enhancing Lives By Changing The Way Water Is Heated
69
11/6/2018