7.
Dräger REGARD 2400 / 2410 and Catalytic Bead
Sensors*
IMPORTANT NOTICE:
If a Dräger REGARD 2400 or Dräger REGARD 2410 should be connected to a catalytic
bead sensor a semi bridge converter has to be used! There are 2 different converters that
could be used:
SC00016
internal converter for Dräger REGARD 2400
3604655
external converter for both versions (exchange for 3603560)
8.

Accessories

8.1. Installation of a Semi-Bridge Converters

Only Dräger REGARD 2400
The catalytic sensor in the Polytron SE Ex forms one half of a Wheatstone bridge while the
converter board has to provide the second half of this bridge. Therefore it is necessary to use
a semi-bridge converter (Part No. SC00016), if one or more Polytron SE Ex sensing heads are
connected to a Dräger REGARD 2400. Thus the converter powers the sensor and converts
the semi-bridge signal into a 4...20 mA signal, suitable for internal processing within the Drä-
ger REGARD 2400.
Procedure:
Switch off the supply voltage.
Remove the short-circuit strap and insert the converter.
*
(Polytron SE Ex sensors)
Dräger REGARD 2400 / 2410 and Catalytic Bead Sensors
Channel D
Channel C
Channel B
Channel A
Accessories