matches that of the OUT:POWer setting. The offset also affects the valid range of the
OUTput:POWer command setting.

4.5.5 OUTput:10Mhz

This command enables/disables the buffered 10 MHz internal oscillator CMOS output on J4 pin 12.
By default the output is disabled to reduce noise and power consumption and must be enabled with
the ON setting. The format of this command is:
OUTput:10Mhz <ON | OFF>
This parameter is stored in NV memory and automatically applied after power-on.

4.5.6 OUTput?

This query command outputs the query responses from the following separate queries:
OUT:POWer?
OUT:OFFset?
OUT:10MHz?

4.6 Calibration Subsystem

The Calibration Subsystem is used for factory calibration of the output power and should not be
user-modified. Please contact JLT for information on recalibrating the output power.

4.7 SYNChronization Subsystem

This subsystem groups the commands related to the phase and frequency synchronization of the RSR
GNSS Transcoder™ with the GPS receiver. The list of the commands supported for this subsystem is
the following:
SYNChronization:SOURce:MODE [GPS|EXTernal|NMEA]
SYNChronization:SOURce:STATE?
SYNChronization:HOLDover:DURation?
SYNChronization:HOLDover:STATe?
SYNChronization:HOLDover:INITiate
SYNChronization:HOLDover:RECovery:INITiate
SYNChronization:OUTput:1PPS:RESET [ON|OFF]
SYNChronization:TINTerval?
SYNChronization:TINTerval:THReshold [50,2000]
SYNChronization:IMMEdiate
SYNChronization:FEEstimate?
SYNChronization:LOCKed?
SYNChronization?