Vidos Duo Series User Manual

2 wire system video door intercom

Advertisement

Quick Links

USER'S MANUAL
duo
2 wire system video door intercom
S1508A
1
2
3
4
5
6
7
8
9
0
#
*
A
B
RF CARD
S1500DA

Door station

S1516
1
2
3
4
5
6
7
8
9
0
#
*
A
B
S1500DLC
RF CARD
S1532A
1
2
3
4
5
6
7
8
9
0
#
*
A
B
S1500DL
W.20181121ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Duo Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Vidos Duo Series

  • Page 1: Door Station

    USER’S MANUAL 2 wire system video door intercom RF CARD S1508A S1516 S1532A RF CARD S1500DA S1500DLC S1500DL Door station W.20181121ENG...
  • Page 2 CHRACTESISTICS OF THE SYSTEM VIDOS is a state-of-the-art solution characterised by its exceptional ease of configuration and installation. The system operation is based on the simplicity of connection through 2 non-polarity wires only.
  • Page 3: Table Of Contents

    CONTENTS Modules..................4 Camera Module................4 Keypad Module................6 TFT Module.................11 Card Reader Module..............12 Call Button Module ..............14 Module Connection..............16 CONFIGURATIONS..............18 Common Door Station Setting ............18 Software Update .................19 Tone Update ................19 Namelist Update .................20...
  • Page 4 INSTALLATION GUIDE DESCRIPTION TERMINAL The door stations are used as speaking and opera t i n g units for the door communication system at the front door.Via t h e door station,a call is connected to the desired home station a f t e r a call button is pressed.
  • Page 5 INSTALLATION GUIDE MOUNTING SYSTEM CONNECTION Standard mounting Code=31 Impedance Code=30 OFF ON switch Code=29 Code=28 Drill a hole and attach the embedded box to it. Wire correctly and plug in the bus line connector Code=7 Code=6 OFF ON Impedance switch Code=5 Code=4 Code=3...
  • Page 6 INSTALLATION GUIDE 2) Door Lock Controlled with External Power DIP SWITCHES SETTING 1. The external power supply must be used according to the lock. Totally 6 bits can be confi gured by dip-switch. Th e switches can be 2. The jumper must be taken off before connecting. modifi...
  • Page 7: Modules

    MODULES • Warning Tune Setting CAMERA MODULE When the door station with Camera Module is in standby. 1. Parts and functions (1)Press Key A and hold on for 3 seconds to enter the Warning Tune Option Mode, the Status indicator turns on and the current tune is Speaker playing;...
  • Page 8: Keypad Module

    MODULES KEYPAD MODULE • The example is set as cancel button and # as confi rm button,please refer to ∗/# function settin g 1. Parts and functions for detail information. • Forbid to slide to touch the digital keypad,it m a y cause mistaken key,the correct operation is using your fi...
  • Page 9 MODULES Input the master code. Beep+, Beep (Default: [ ] +[#] ) 1.Reset all settings 2.Setting the master code 3.Setting the key 4.Setting the illumination time unlock time (Default 1234) (Default 10s) (Default 1s) Input the setting code. Input the setting code. Input the setting code.
  • Page 10 MODULES Input the master code. Beep+, Beep (Default: [ ] +[#]) 5.Setting the unlock mode 6.Setting operation tone 7.Reset code setting 8. &# function setting (Default 0(opened)) (Default ON) (Default Normal) Input the setting code. Input the setting code. Input the setting code. Input the setting code.
  • Page 11 MODULES Input the master code. Beep+, Beep (Default: [ ] +[#]) 9. Call tone setting 10.Interference resistant 11.SPK volume adjust 12.Night light level grade setting setting setting (Default enable) (Default 2) (Default:4) (Default 4) Input the setting code. Input the setting code. Input the setting code.
  • Page 12 MODULES Input the master code. Beep+, Beep (Default: [ ]+[#] ) 16.Setting the code 17.Setting the code 18.Setting the code 19.Setting the code forTemporary1 forTemporary2 for user group1 for user group2 20~59 60~99 Input the setting code. Input the setting code. Input the setting code.
  • Page 13: Tft Module

    MODULES • Calling Display TFT DISPLAY MODULE This is the user interface of calling process. (Kn o w that if the name list is created, the resident’s name will be showed on screen) 1. Parts and functions Press * (Keypad Module) to cancel the call. Mounting screw 3.5 inch TFT...
  • Page 14: Card Reader Module

    MODULES iii) When input admin code,a Setting Code will be asked on TFT CARD READER MODULE screen. 1. Parts and functions Mounting screw Swiping card area LED indicator • Combin with ID module This is the user interface when the right card has been read.the info of “Door1 open”...
  • Page 15 MODULES • User Card Setting iii) Format Card Power on and short out EB+,EB- , a sound of “BP+” will be sent out, In standby mode, show the MASTER CARD DELETE, it will sound and the Unlock indicator is turned on. “BP+,BP”, and the Unlock indicator is turned on.
  • Page 16: Call Button Module

    MODULES • Combin With Keypad Module CALL BUTTON MODULE 1. Parts and functions Mounting screw Call button Name plate Double row call button module Mounting screw 1) Master Card Setting(Reserve) Name plate 2) Add Card Setting(Reserve) Call button 2) Delete Card Setting(Reserve) Single row call button module •...
  • Page 17 MODULES In the case of single row buttons: • DIP3 switch set to off 4 5 6 RF CARD RF CARD • DIP3 switch set to on 4 5 6 RF CARD RF CARD 3. Address description Functions Call apartment 01 Call apartment 02 Call apartment 03 Call apartment 04...
  • Page 18: Module Connection

    MODULE CONNECTION • Card reader module TERMINAL DESCRIPTION • Video entry module INPUT OUTPUT Name Descriptions Name Descriptions JWGN1 Connect to CN/WGN of video entry module DIP switches for system confi gurations JKB' Connect to next call button module JP-LK For electronic lock safety type setting Connect to next call button module CN/KMB...
  • Page 19 MODULE CONNECTION CONNECTIONS • S1500DA • S1508A CN/KMB CN/FUN CN/FUN CN/WGN INPUT INPUT OUTPUT OUTPUT INPUT INPUT OUTPUT RF CARD • S1516 • S1532A CN/KMB INPUT INPUT CN/KMB CN/WGN OUTPUT INPUT OUTPUT INPUT OUTPUT OUTPUT INPUT INPUT INPUT RF CARD OUTPUT OUTPUT OUTPUT...
  • Page 20: Configurations

    CONFIGURATIONS 4.Calling COMMON DOOR STATION SETTING • Calling By Buttons 1.Namelist.txt Setting: Press the call button to call corresponding monitors. has its meaning, see the following picture. Description: Button: S1500 button which you need to set. • Calling By Namelist Name: It will be displayed on TFT module.
  • Page 21: Software Update

    CONFIGURATIONS SOFTWARE UPDATE TONE UPDATE 1. Format SD card. 1. Format SD card S1500 3.Update software: 3.Update ringtone: i) Power on the S1500, and set DIP6 switch to ON, as the following i) Power on the S1500, and set DIP6 switch to ON, as the following picture shows: picture shows: DIP6=ON...
  • Page 22: Namelist Update

    NAMELIST UPDATE UI UPDATE • Update by SD card 1. Format SD card. 1. Format SD card. 3.Update namelist: i) Power on the S1500, and set DIP6 switch to ON, as the following 3.Update UI. picture shows: DIP6=ON 1 2 3 4 5 CN/KMB CN/WGN 4.Insert the SD card to slot on the PCB of TFT module.
  • Page 23 9.Cables Requirements The maximum distance of the wiring is limited in th e DUO system. Using different cables may also affect the maximum distance which the system can reach. The farest monitor monitor with two or four monitors monitor monitor M-SM4 100~240VAC When Monitor quantity <...
  • Page 25: Warranty Card

    8. The condition to perform repair works is to deliver the Product with the Warranty Card and the proof of purchase. 9. Service Centre: Firma Handlowa Wena Al. Jerozolimskie 311 , 05 - 816 Reguły / near Warsaw Poland tel. +48 228 370 286; +48 228 174 003 e-mail: biuro@vidos.pl www.vidos.pl -21-...
  • Page 28 Firma Handlowa Wena l. Jerozolimskie 311 05-816 Reguły/ near Warsaw Poland tel. +48 228 370 286; +48 228 174 008 e-mail: biuro@vidos.pl www.vidos.pl...