Cabinet Assembly and Cable Installation

2.1 In This Chapter

This chapter includes:

Entry system interface cabling

Entry system power cabling
Expanded system cabinet preparation
Expanded system cabinet assembly
Expanded system interface cabling
Expanded system power cabling
2.2 Entry System Interface Cabling
To install the entry system interface cables, perform the steps in Table 2–1.
Table 2–1 Entry System Interface Cabling
Step
Action
1.
Open the cross-link assembly kit (PN 70-30588-01). Remove the contents.
2.
Install cross-link module 1 into slot 1 of the Zone A miscellaneous module card
cage.
3.
Install cross-link module 2 into slot 1 of the Zone B miscellaneous module card
cage.
The cables described in steps 4 to 7 have been installed at the factory.
These steps are included in case any cable connectors were accidentally
disconnected.
4.
Connect one end of a Disk Out cable (PN 17-03537-02) to the left connector of the
Zone A Disk In/Disk Out module located in slot 4 of the miscellaneous module card
cage. Connect the other end of the Disk Out cable to the connector of the Zone B
DSSI interface module in slot 16 of the interface module card cage.
5.
Connect one end of a Disk Out cable (PN 17-03537-02) to the left connector of the
Zone B Disk In/Disk Out module located in slot 4 of the miscellaneous module card
cage. Connect the other end of the Disk Out cable to the connector of the Zone A
DSSI interface module in slot 16 of the interface module card cage.
Note
(continued on next page)
Cabinet Assembly and Cable Installation 2–1