Black Box Hardened Managed Ethernet Switch
Hardened Managed
Ethernet Switch
LEH8814,
LEH813 Series,
LEH812 Series,
LEH808 Series
E-mail: info@blackbox.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Black Box LEH808 Series

  • Page 1 FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or Fax SUPPORT 724-746-0746 INFORMATION Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 2: Quick Start Guide

    Black Box Hardened Managed Ethernet Quick Start Guide This quick start guide describes how to install and use the Hardened Managed Ethernet Switch. This is th choice for harsh environments constrained by spa Physical Description The Port Status LEDs and Power Inputs...
  • Page 3: Functional Description

    DC JACK with 100-240VAC external power supply. to 75 (-40℉ to 167℉) operating temperature range. Tested for functional operation @ -40 Supports Din-Rail, Panel, or Rack Mounting installation. User’s Manual Black Box Hardened Managed Ethernet Switch 12VDC DC Jack + 12-32VDC - Power Ground Terminal Block +...
  • Page 4: Console Configuration

    Black Box Hardened Managed Ethernet Switch Console Configuration Connect to the switch console: Connect the DB9 null-modem or cross over cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application. Direct access to the...
  • Page 5: Web Configuration

    “switch_a(config)#” prompt will show on the screen. Web Configuration Login the switch: Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below: User’s Manual Black Box Hardened Managed Ethernet Switch in “enable”...
  • Page 6 Black Box Hardened Managed Ethernet Switch Enter the factory default login ID: root. Enter the factory default password (no password). Then click on the “Login” button to log on to the switch. User’s Manual...
  • Page 7: Preface

    To get the most out of this manual, you should have an understanding of Ethernet networking concepts. In this manual, you will find: Features on the Hardened Managed Ethernet Switch Illustrative LED functions Installation instructions Management Configuration SNMP, DHCP, IGMP… Specifications User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 8: Table Of Contents

    Black Box Hardened Managed Ethernet Switch Table of Contents UICK TART UIDE HYSICAL ESCRIPTION The Port Status LEDs and Power Inputs ... UNCTIONAL ESCRIPTION ONSOLE ONFIGURATION ONFIGURATION REFACE ABLE OF ONTENTS RODUCT VERVIEW LACK ARDENED ACKAGE ONTENTS RODUCT IGHLIGHTS Basic Features ... 11 Management Support ...
  • Page 9: Onsole M Anagement

    STP / R VLAN... S... SNMP... 802.1 THER ROTOCOLS PECIFICATIONS A ...154 PPENDIX B ...155 PPENDIX User’s Manual Black Box Hardened Managed Ethernet Switch ...25 ANAGEMENT MIB ( RFC 1493) ... RIDGE ... 26 ... 27 ANAG EMENT ROWSER NTERFACE ONSOLE ANAGEMENT ...152...
  • Page 10: Product Overview

    When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller. • The Black Box Hardened Managed Ethernet Switch • User’s Manual • RS232 cable •...
  • Page 11: Product Highlights

    IEEE802.1x Port-based Network Access Control PORT-MIRRORING Port-mirroring QOS (IEEE802.1p Quality of Service) 4 priority queues User’s Manual Black Box Hardened Managed Ethernet Switch & TS2 Environmental requirements for Traffic Generic standard buffer E802.3x full-duplex compliant flow to 167 ) operating temperature range...
  • Page 12 Black Box Hardened Managed Ethernet Switch INTERNETWORKING PROTOCOLS Bridging: IEEE802.1w Rapid Spanning Tree IEEE802.1D Spanning Tree compatible IEEE802.1Q – GVRP Ring IP Multicast: IGMP Snooping Rate Control NETWORK MANAGEMENT METHODS Console port access via RS-232 cable (CLI, Command Line Interface)
  • Page 13: Front Panel Display

    Front Panel Display  P OWER This LED comes on when the switch is properly connected to power and turned on.  P ort Status LEDs The LEDs are located at the left side of the front panel, displaying status for each respective port.
  • Page 14: Physical Ports

    Black Box Hardened Managed Ethernet Switch Physical Ports The Black Box Hardened 14-port 10/100Base-TX Hardened 13-port 10/100Base-TX + 1-port 1 Hardened Managed Ethernet Sw 12-port 10/100Base-TX + 2-port 100Base-FX Hardened Managed Ethernet Switch 8-port 10/100Base-TX + 2-port 100Base-FX Hardened Managed Ethernet Switch...
  • Page 15: Switch Management

    Netscape or Internet Explorer browser. Administration console via RS-232 serial port (CLI) The switch provides an onboard serial port, which allows the switch to be configured via a directly connected terminal. External...
  • Page 16: Installation

    DC outlet with a voltage range from 12 to 32 VDC. Turn on the DC power supply. Step 2: Turn off the DC power supply if you want to shut down the switch. structions about how to...
  • Page 17: Connecting To Your Network

    Rear view Connecting to Your Network Cable Type & Length It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements. Cable Specifications User’s Manual...
  • Page 18 Black Box Hardened Managed Ethernet Switch Speed Connector 10Base-T RJ-45 100Base-TX RJ-45 1000Base-T RJ-45 100Base-FX ST, SC (*Wavelength of 1300nm) 100Base-FX (*Wavelength of 1300nm) 1000Base-SX (*Wavelength of 850nm) 1000Base-LX (*Wavelength of 1300nm) Port Cable Spee Half/F Duple 10/20 Mbps 2-pair UTP/STP Cat.
  • Page 19: Cabling

    Cabling Step 1: First, ensure the power of the switch and end devices are turned off. Always ensure that the power is off before any installation. <Note> Step 2: Prepare cable with corresponding connectors for each type of port in use.
  • Page 20: Switch Management

    Black Box Hardened Managed Ethernet Switch Switch Management This chapter explains the meth configure management access to types of management applicatio and management protocols that management device (workstation the system. It also contains inform options. This chapter covers the following topics: •...
  • Page 21: Administration Console (Cli)

    Black Box Hardened Managed Ethernet Switch Administration Console (C The administration cons ole is an internal, character-o riented, Command Line Interface (CLI) for performin g system administration such as di splaying statistics or chan ging option settings. Using this method, you can view...
  • Page 22: Modem Access

    The switch provides a browse configure and manage the switch re After you set up your IP address for the switch, you can access the switch’s web interface applications directly in your web browser by entering the IP address of the switch. You...
  • Page 23: Protocols

    User’s Manual Black Box Hardened Managed Ethernet Switch protocols: rogram, such as Telnet, that allows rom a Macintosh, a PC, or a UNIX...
  • Page 24: Web-Based Browser Management

    Black Box Hardened Managed Ethernet Switch Web-Based Browser Management The switch provides a web-based browser interface for configuring and managing the switch. This interface allows you to access the switch using a preferred web browser. This chapter describes how to configure the switch using its web-based browser interface.
  • Page 25: User's Manual

    SNMP Agent and MIB-2 (RFC 1213) The SNMP Agent running on the switch manager CPU is responsible for: User’s Manual Black Box H r a d ned Managed Ethernet Switch anagement switch’s Simple Network and Remote Monitoring RMON is a system defined...
  • Page 26: Rmon Mib (Rfc 1757) And Bridge Mib (Rfc 1493)

    RMON MIB definition. RMON Groups Supported The switch supports the following RMON MIB groups defined in RFC 1757: - RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.
  • Page 27: Bridge Groups Supported

    The action taken in the Network Management Station depends on the specific network management application. Bridge Groups Supported The switch supports the following four groups of Bridge MIB (RFC 1493): - The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.
  • Page 28: Web-Based Browser Management

    This chapter describes how to configure the switch using its web-based browser interface. Logging on to the switch SWITCH IP ADDRESS In your web browser, specify the IP address of the switch. Default IP address is 192.168.1.10. LOGIN Enter the factory default login ID: root.
  • Page 29 Black Box Hardened Managed Ethernet Switch PASSWORD Enter the factory default password (no password). Or enter a user-defined password if you followed the instructions later and changed the factory default password. Then click on the “Login” button to log on to the switch. User’s Manual...
  • Page 30: Understanding The Browser Interface

    Black Box Hardened Managed Ethernet Switch Understanding the Browser Interface The web browser interface provid es gro ups of point-and-click buttons at the left field of the screen for configuring and managing the switch. SYSTEM System Information, System/Password, IP Address, Save Configuration,...
  • Page 31 Black Box Hardened Managed Ethernet Switch VLAN VLAN Mode Setting, 802.1Q VLAN Port Setting, 802.1Q Port Setting, Port Based VLAN Global Configuration, 802.1p priority, DSCP SNMP SNMP General Setting, SNMP v1/v2c, SNMP v3 802.1X Radius Configuration, Port-Based Authentication OTHER PROTOCOLS GVRP, IGMP Snooping, NTP User’s Manual...
  • Page 32: System

    Black Box Hardened Managed Ethernet Switch System System Information View System information, VLAN ID, IP Address, and IP Subnet Mask of the Switch. User’s Manual...
  • Page 33 Password: Click in “Password” text box. Type a password. Retype Password: Click in “Retype Password” text box. Type the same password in “Password” text box again to verify it. Updating setting: Click “Updating setting” button to update your settings. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 34 Black Box Hardened Managed Ethernet Switch IP Address IP Address: Click in “IP Address” text box and type a new address to change the IP Address. IP Subnet Mask: Click in “IP Subnet Mask” text box and type a new address to change the IP Subnet Mask.
  • Page 35 Auto save interval (5~65536 sec): Click in “Auto save interval” text box and type a decimal number between 5 and 65536. Submit: Click “Submit” button when you finished Auto save configuration. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 36 Black Box Hardened Managed Ethernet Switch Firmware Upgrade Filename: Click in “Filename” text box and type the name of the file that you intend to upgrade it to the switch. TFTP server IP: Click in “TFTP server IP” text box and type the TFTP server IP address from where the file will be obtained.
  • Page 37 Black Box Hard ened Managed Ethernet Switch Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time. User’s Manual...
  • Page 38 Black Box Hardened Managed Ethernet Switch User’s Manual...
  • Page 39 Black Box Hardened Managed Ethernet Switch Firmware has been upgraded successfully to the switch. Reboot the switch after completing the upgrade process. User’s Manual...
  • Page 40 Black Box Hardened Managed Etherne witch Reboot Reboot: Click “Reboot” button to restart the switch. User’s Manual...
  • Page 41 Black Box Hardened Managed Ethernet Switch Logout Logout: Click “Logout” button to logout of the switch. User’s Manual...
  • Page 42: Port

    Black Box Hardened Managed Ethernet Switch Port Configuration Admin Setting: Click “Admin Setting” drop-down menu to choose “Link down” or “Link up” from the “Admin Setting” drop-down list to disable or enable Admin Setting for the port. Speed: Click “Speed” drop-down menu to change the line speed and duplex settings from the “Speed”...
  • Page 43 Black Box Hardened Managed Ethernet Switch Port Status View the Link Status, Speed, Duplex, and Flow control status for all ports. User’s Manual...
  • Page 44 Black Box Hardened Managed Ethernet Switch Rate Control Ingress: Click in “Ingress” text box and type a new Rate to change the Ingress Rate Control for the port. Rate Values: 64kbps, 128kbps, 192kbps, … , 1.792mbps; 2mbps, 3mbps, 4mbps, … , 100mbps; 104mbps, 112mbps, 120mbps, … , 1000mbps.
  • Page 45 Black Box Hardened Managed Ethernet Switch RMON Statistics Click Port 1 ~ Port 14 to view corresponding RMON Statistics. User’s Manual...
  • Page 46 Black Box Hardened Managed Ethernet Switch Per Port Vlan Activities Click Port 1 ~ Port 14 to view corresponding vlan activities. User’s Manual...
  • Page 47: Switching

    Storm-control enabled type: Choose “Broadcast” and/or “DLF-Multicast” from “Storm-control enabled type” for the port. Update Setting: Click “Update Setting” button when you finished Threshold level and Storm-control enabled type settings. User’s Manual Black Box Hardened Managed Ethernet Switch port. Need choose “Broadcast”...
  • Page 48 Black Box Hardened Managed Ethernet Switch Static MAC Entry Static-MAC-Entry Forward: Add MAC address: Click in “Add MAC address” text box and type a locked forwarding MAC address for the port. VLAN ID: Click “VLAN ID” drop-down menu and choose a VLAN ID from the “VLAN ID”...
  • Page 49 (Port 1 ~ Port 14) from “Mirror To” drop-down list. Mirror Mode: Click “Mirror Mode” drop-down menu to Choose “Tx/Rx”, “Tx”, or “Rx” from “Mirror Mode” drop-down list. Submit: Click “Submit” button when you finished Port Mirroring settings. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 50: Trunking

    Black Box Hardened Managed Ethernet Switch Trunking Port Trunking Static Channel Group: Trunk 1: Click Port 1 ~ Port 12 to assign ports to Trunk 1. (Maximum 4 ports in Trunk 1.) GE Trunking: Trunk 3: Click “Static” or “Disable” for Trunk 3.
  • Page 51: Stp / Ring

    4 and 30. STP Version: Click “STP Version” drop-down menu to choose “RSTP” or “STP compatible” from “STP Version” drop-down list. Update setting: Click “Update setting” button when you finished Global User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 52 Black Box Hardened Managed Ethernet Switch Configuration. RSTP Port Setting STP Version: Click “STP Version” drop-down menu to choose “RSTP” from “STP Version” drop-down list. Port: Click “Port” drop-down menu to Choose Port 1 ~ Port 14 from “Port” drop-down list.
  • Page 53 Ring port 2: Click “Ring port 2” drop-down menu to choose Ring port 2 from “Ring port 2” drop-down list. Update setting: Click “Update setting” button when you finished Set ring port. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 54: Vlan

    Black Box Hardened Managed Etherne VLAN VLAN Mode Setting VLAN Mode Setting: Click “VLAN Mode Setting” drop-down menu to Choose “Tag-based VLAN” or “Port-based VLAN” from “VLAN Mode Setting” drop-down list. Update Setting: Click “Update Setting” button when you finished VLAN Mode Setting.
  • Page 55 Black Box Hardened Managed Ethernet Switch User’s Manual...
  • Page 56 Black Box Hardened Managed Etherne 802.1Q VLAN Setting Add VLAN: VLAN setting: Click “VLAN setting”. The “VLAN Setting” window appears. Add VLAN: Click “Add VLAN” button to create a new VLAN from “VLAN Setting” window. VLAN ID(2-4094): Click in the “VLAN ID” textbox and specify a new VLAN ID number from 2 ~ 4094.
  • Page 57 Select a VLAN ID: Click “Select a VLAN ID” drop-down menu from “Select a VLAN ID” drop-down list to choose the VLAN to be deleted. Submit: Click “Submit” button when you finished VLAN setting. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 58 Black Box Hardened Managed Ethernet Switch 802.1Q Port Setting VLAN Port Setting: Click “VLAN Port Setting”. The “VLAN Port Setting” window appears. Mode: Click “Mode” drop-down menu to Choose “Access”, “Trunk”, or “Hybrid” from “Mode” drop-down list for the port. The port will be Tag port if you choose “Trunk”...
  • Page 59 Black Box Hardened Managed Ethernet Switch Port Based VLAN VLAN: Choose the port to be added to or deleted from the VLAN. User’s Manual...
  • Page 60 Black Box Hardened Managed Ethernet Switch Select all: Click “select all” button to choose Port 1 ~ Port 14 all to be added to the VLAN. Delete all: Click “delete all” button to choose Port 1 ~ Port 14 all to be deleted from the VLAN.
  • Page 61: Qos

    QoS: Click “QoS” drop-down menu from “QoS” drop-down list to choose “Enable” or “Disable” to enable or disable QoS. Trust: Enable or disable the switch port to trust the CoS (Class of Service) labels of all traffic received on that port. Enable or disable a routed port to trust the DSCP (Differentiated Service Code Point) labels of all traffic received on that port.
  • Page 62 Black Box Hardened Managed Ethernet Switch 802.1p Priority Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for VLAN Priority 0 ~ 7. Submit: Click “Submit” button when you finished 802.1p priority. User’s Manual...
  • Page 63 DSCP Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for DSCP Priority 0 ~ 63. Submit: Click “Submit” button when you finished DSCP. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 64: Snmp

    Black Box Hardened Managed Ethernet Switch SNMP SNMP General Setting SNMP Status: Click “SNMP Status” drop-down menu from “SNMP Status” drop-down list to choose “Enable” or “Disable” to enable or disable SNMP. Description: Click in the “Description” textbox and specify a new description for SNMP.
  • Page 65 “Topology Change Trap” drop-down list to choose “Enable” or “Disable” to enable or disable topology change trap. 13. Update Setting: Click “Update Setting” button when you finished SNMP General Setting. User’s Manual Black Box Hardened Managed Ethernet Switch ble or disable authentication failure...
  • Page 66 Black Box Hardened Managed Ethernet Switch SNMP v1/v2c Get Community Name: Click in the “Get Community Name” textbox and specify a get community name. Set Community Name: Click in the “Set Community Name” textbox and specify a set community name.
  • Page 67 Access Mode: Click “Access Mode” drop-down menu from “Access Mode” drop-down list to choose “Read Only” or “Read/Write”. Read Only: Add a user using SNMP v3 with read-only access mode. User’s Manual Black Box Hardened Managed Ethernet Switch authentication password. authentication password.
  • Page 68 Black Box Hardened Managed Ethernet Switch Read/Write: Add an mode Sumit: Click “Sumit” button Delete User: Delete User: Click “Delete User” button. The “Select User Name” window appears. Select User Name: Click “Select User Name” drop-down menu from “Select User Name” drop-down list to choose the user to be deleted from using SNMP v3.
  • Page 69 Radius Status: Click “Radius Status” drop-down menu from “Radius Status” drop-down list to choose “Enable” or “Disable” to globally enable or disable authentication. Update Setting: Click “Update Setting” button when you finished Radius Status Setting. User’s Manual Black Box Hard ened Managed Ethern et Switch...
  • Page 70 Timeout <1-1000>: Click in the “Timeout” textbox and specify the time interval (in seconds) that the Switch waits for the radius server to reply before retransmitting. Enter a value in the range 1 to 1000.
  • Page 71 “Select Radius Server IP” drop-down list to choose the IP address of the remote radius server host to be deleted. Sumit: Click “Sumit” button when you finished radius server deletion. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 72 Black Box Hardened Managed Ethernet Switch Port-Based Authentication Interface: Click “Interface” drop-down menu from “Interface” drop-down list to choose the port to be set port-based authentication. Authentication State: Click “Authentication State” drop-down menu from “Authentication State” drop-down list to choose “Enable” or “Disable” to enable or disable authentication state.
  • Page 73 Update Setting: Click “Update Setting” button when you finished port-based authentication setting. User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 74: Other Protocols

    Black Box Hardened Managed Ethernet Switch Other Protocols GVRP GVRP Global Setting: GVRP: Click “GVRP” drop-down menu from “GVRP” drop-down list to choose “Enable” or “Disable” to enable or disable GVRP (GARP VLAN Registration Protocol). Dynamic VLAN creation: Click “Dynamic VLAN creation” drop-down menu from “Dynamic VLAN creation”...
  • Page 75 IGMP Snooping IGMP mode: Click “IGMP mode” drop-down menu from “IGMP mode” drop-down list to choose “Disable”, “Passive”, or “querier” for the switch. Disable: Disable IGMP on the switch. Passive: The switch with only multicast-data-forwarding capability. Querier: The switch acts as the User’s Manual...
  • Page 76 When IGMP router suppression is enabled, the switch sends the first IGMP report from all hosts for a group to all the multicast routers. The switch does not send the remaining IGMP reports for the group to the multicast routers. This feature prevents duplicate reports from being sent to the multicast devices.
  • Page 77 Update Setting: Click “Update Setting” button when you finished NTP Setting. Daylight Saving Setting: Daylight Saving Mode: Click “Daylight Saving Mode” drop-down menu from “Daylight Saving Mode” drop-down list to choose “Disable”, User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 78 Black Box Hardened Managed Ethernet Switch “Weekday”, or “Date” to choose disable, weekday, or date daylight saving for the Switch. Time Set Offset (1-1440 min): Click in the “Time Set Offset” textbox and specify the offset time of daylight saving.
  • Page 79: Command Line Console Management

    Black Box Hardened Managed Ethernet Switch Command Line Conso le M anagement The switch provides a comman d line console interface fo configuration purposes. The swit ch can be configured either locally through its RS-232 port or remotely via a Telnet session.
  • Page 80: Exec Mode (View Mode)

    Black Box Hardened Managed Ethernet Switch Exec Mode (View Mode) Logon to Exec Mode (View Mode) At the switch_a login: prompt just type in “root” and press <Enter> to logon to Exec Mode (or View Mode). switch_a login: root User’s Manual...
  • Page 81 “?” to display the command keywords or parameters along with a short description. switch_a>show ? User’s Manual Black Box Hardened Managed Ethernet Switch y. Access this help by typing in the ng a question mark “?”. The CLI parameters along with a sh...
  • Page 82 Black Box Hardened Managed Ethernet Switch Login timed out The login session to Exec Mode (or View Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
  • Page 83 Exec Mode (or View Mode). switch_a login: root Exit from Exec Mode (View Mode) At the switch_a> prompt just type in “exit” and press <Enter> to exit from Exec Mode (or View Mode). switch_a>exit User’s Manual Black Box Harden ed Managed E thernet Switch...
  • Page 84: Privileged Exec Mode (Enable Mode)

    Black Box Hardened Managed Ethernet Switch Privileged Exec Mode (Enab Logon to Privileged Exec Mode (Enable At the switch_a> prompt just type in “ena Privileged Exec Mode (or Enable Mode). show on the screen. switch_a>enable Commands Privileged Exec Mode (or Enable Mode) allows users to run commands as following.
  • Page 85 Black Box Hardened Managed Ethernet Switch At the switch_a# prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a#show ? User’s Manual...
  • Page 86 Black Box Hardened Managed Ethernet Switch Login timed out The login session to Privileged Exec Mode (or Enable Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
  • Page 87 Exit from Privileged Exec Mode (or Enable Mode) At the switch_a# prompt just type in “exit” and press <Enter> to exit from Privileged Exec Mode (or Enable Mode). switch_a#exit User’s Manual Black Box Harden ed Managed E thernet Switch...
  • Page 88: Configure Mode (Configure Terminal Mode)

    Black Box Hardened Managed Ethernet Switch Configure Mode (Configure Terminal Mode) Logon to Configure Mode (Configure T At the switch_a# prompt just type in “con to logon to Configure Mode (or Config switch_a(config)# prompt will show on the screen. switch_a#configure terminal...
  • Page 89 Black Box Hardened Managed Ethernet Switch At the switch_a(config)# prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a(config)#show ? User’s Manual...
  • Page 90 Black Box Hardened Managed Ethernet Switch Login timed out The login session to Configure Mode (or Configure Terminal Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen.
  • Page 91 Black Box Hardened Managed Ethernet Switch Exit from Configure Mode (or Configure Terminal Mode) At the switch_a(config)# prompt just type in “exit” and press <Enter> to exit from Configure Mode (or Configure Terminal Mode). switch_a(config)#exit User’s Manual...
  • Page 92: System

    Use the no hostname command to disab Command Syntax: (no) hostname HOSTNAME HOSTNAME specifies the network name of the system. Example: The following example sets the hostname to switch, and shows the change in the prompt: switch_a(config)#hostname switch switch(config)# Password: Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode).
  • Page 93 Use ip default-gateway command to set the IP address of the default gateway. Use the no ip default-gateway command to remove the IP address of the default gateway. Command Syntax: User’s Manual Black Box H ardened Managed E w on the screen. subnet subnet mask,...
  • Page 94 Black Box Hardened Managed Ethernet Switch ip default-gateway IP-ADDRESS no ip default-gateway IP-ADDRESS A.B.C.D specifies the IP address of the default gateway. Example: The following example sets the default ga switch_a(config)#ip default-gate switch_a(config)# DNS Server: Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode).
  • Page 95 The following example specifies writing configurations to the file to be used at startup to switch: switch_a#copy running-config startup-config switch_a# User’s Manual Black Box Hardened Managed Ethernet Switch ng confi uration file (file name: WORD) 0) to switch: on the screen. configuration file to tftp server.
  • Page 96 Black Box Hardened Managed Ethernet Switch Restore Default: Command Mode: Privileged Exec mode Logon to Privileged Exec Mode The switch_a# prompt will show on the s switch_a# Usage: Use restore default command to restore Command Syntax: restore default Example: The following example restores default setting of the switch:...
  • Page 97 Logon to Privileged Exec Mode (Enable Mode). The switch_a# prompt will show on the screen. switch_a# Usage: Use install image command to upgrade firmware from tftp server to switch. Command Syntax: install image IP-ADDRESS WORD IP-ADDRESS specifies the IP address of tftp server.
  • Page 98 Black Box Hardened Managed Ethernet Switch At the “switch_a#” prompt just type in “reload” and press <Enter> to reboot the switch after completing the upgrade process. User’s Manual...
  • Page 99 Use logout command to exit from the Exec mode or Privileged Exec mode. Command Syntax: logout Example: The following example specifies to exit from the Exec mode or Privileged Exec mode. switch_a>logout switch_a login: User’s Manual Black Box H ardened Managed ed Exec mode ode). Ethernet Switch...
  • Page 100: Port

    Black Box Hardened Managed Ethernet Switch Port Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities. Configuration Admin Setting: Command Mode: Interface mode Logon to Configure Mode (Configure Termin Then logon to Interface mode. fe1 means port 1.
  • Page 101 The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a# Usage: Use the show interface command to display interface configuration and User’s Manual Black Box Hard ened Managed Ethern ode: auto, full, half. plex MODE (full) to the interface al Mode). et Switch...
  • Page 102 Black Box Hardened Managed Ethernet Switch status. Command Syntax: show interface IFNAME IFNAME specifies the name of the configuration information is desired. Example: The following example shows the use of s configuration and status of the interface fe switch_a>show interface fe1...
  • Page 103 Example: The following is an output of show vlan command displaying information about VLAN 2: switch_a>show vlan 2 User’s Manual Black Box Hardene and to display RMON face for which RMON statistics is d Manage d Ethernet Switch statistics of...
  • Page 104: Switching

    Black Box Hardened Managed Ethernet Switch Switching Bridging, Static MAC Entry, Port Mirroring Bridging Aging Time (seconds): Command Mode: Configure mode Logon to Configure Mode (Configure Termin The switch_a(config)# prompt will show on the screen. switch_a(config)# Usage: Use this command to specify an ageing-o The learned MAC address will persist till this specified time.
  • Page 105 The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use storm-control multicast enable command to enable multicast traffic. Use no storm-control multicast command to disable multicast traffic. User’s Manual Black Box Hardened Managed Ethernet Switch -control level LEVEL (30) to the inal Mode). screen.
  • Page 106 Black Box Hardened Managed Etherne t Switch Command Syntax: storm-control multicast enable no storm-control multicast Example: The following example shows setting stor interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control multicas switch_a(config-if)# DLF: Command Mode: Interface mode Logon to Configure Mode (Config Then logon to Interface mode.
  • Page 107 The following example configures a bridge GROUP (1) to discard matching frames (MAC address 2222.2222.2222) to the interface fe1 (port 1): switch_a(config)#bridge 1 address 2222.2222.2222 discard fe1 switch_a(config)# User’s Manual Black Box Hardened Managed Ethernet Switch a bridge entry to forward matching AME VLANID IFNAME VLANID ridging.
  • Page 108 Black Box Hardened Managed Ethernet Switch Port Mirroring Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use this command to define a mirror source port and its direction.
  • Page 109: Trunking

    <1-3> Channel group number. Maximum 4 ports in static-channel-group 1 and static-channel-group 2. Maximum 2 ports in static-channel-group 3 Example: following example static-channel-group 1: switch_a(config)#interface fe1 switch_a(config-if)#static-channel-group 1 switch_a(config-if)# User’s Manual Black Box Hardened Managed Ethernet Switch adding interface (port...
  • Page 110: Stp / Ring

    Black Box Hardened Managed Ethernet Switch STP / Ring Global Configuration, RSTP Port Global Configuration STP Version: Command Mode: Configure mode Logon to Configure Mode (Config The switch_a(config)# prompt will show switch_a(config)# Usage: Use this command to choose the Spanni Tree protocol on a bridge.
  • Page 111 Use this command to set bridge priority for the common instance. Using a lower priority indicates a greater likelihood of the bridge becoming root. Command Syntax: User’s Manual Black Box Harde ned Managed Et es the rapid-spanning-tree on tree enable al Mode).
  • Page 112 Black Box Hardened Managed Ethernet Switch bridge GROUP priority PRIORITY no bridge GROUP priority GROUP <1-1> The ID of the b PRIORITY <0-61440> The bridge priority Example: The following example sets the priority PRI (1): switch_a(config)#bridge 1 priority 4096 switch_a(config)# Hello Time (sec) (1..9):...
  • Page 113 Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. User’s Manual Black Box Hardened Managed Ethernet Switch to which this maximum age time time, in seconds, to lis AXAGE (28) of br inal Mode).
  • Page 114 Black Box Hardened Managed Ethernet Switch The switch_a(config-if)# prompt will show switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use this command to set the port priorit indicates a greater likelihood of the bridge becoming root. Command Syntax: bridge GROUP priority PRIORITY GROUP <1-1> the ID of the bridge group.
  • Page 115 Use the no spanning-tree autoedge command to disable this feature. Command Syntax: (no) spanning-tree autoedge User’s Manual Black Box Hardened Managed Ethernet Switch ure Terminal Mode). w on the screen. command to set the link mmand to set a p...
  • Page 116 Black Box Hardened Managed Ethernet Switch Example: The following example enables the spannin fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree autoedge switch_a(config-if)# Edgeport: Command Mode: Interface mode Logon to Configure Mode (Configure Term Then logon to Interface mode. fe1 means port 1.
  • Page 117 RING_PORT_1 Specify the Ring port 1. RING_PORT_2 Specify the Ring port 2. Example: The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2: switch_a(config)#ring set-port fe1 fe2 switch_a(config)# User’s Manual Black Box Harden ed Managed Ethe rnet Switch...
  • Page 118: Vlan

    Black Box Hardened Managed Etherne VLAN VLAN Mode Setting, 802.1Q VLAN Setting, VLAN 802.1Q VLAN Setting VLAN Database: Command Mode: Configure mode Logon to Configure Mode (Configure Term The switch_a(config)# prompt will show switch_a(config)# Usage: Use vlan database command to enter the...
  • Page 119 Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. User’s Manual Black Box Hardened Managed Ethernet Switch LANID (2) and name VL e vlan2 state enable inal Mode). AN_NAME...
  • Page 120 Black Box Hardened Managed Ethernet Switch switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use switchport mode hybrid command to of the Layer-2 interface as hybrid, and classify both tagged and untagged frames. Use the no switchport hybrid command interface to access (default). Command Syntax:...
  • Page 121 2 egress-tagged enable switch_a(config-if)# switch_a(config-if)# Switchport trunk allowed vlan: User’s Manual Black Box Hardened Managed Ethernet Switch will show on the screen. cteristics of the Layer-2 interface mes will be classifie ybrid switching. l Mode).
  • Page 122 Black Box Hardened Managed Ethernet Switch Command Mode: Interface mode Logon to Configure Mode (Configure Termi Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use this command to set the switching cha to trunk.
  • Page 123 VLANID The ID of the VLAN will be added to or removed from the Layer-2 interface. Example: The following example specifies to add the interface fe1 (port 1) to VLANID (2): switch_a(config)#interface fe1 switch_a(config-if)#switchport portbase add vlan 2 switch_a(config-if)# User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 124: Qos

    Command Syntax: (no) mls qos trust cos/dscp cos Class of Service. dscp Differentiated Service Code Point. Example: The following example turns on QoS trust CoS on the switch: switch_a(config)#mls qos trust cos switch_a(config)# witch ure Terminal Mode). on the screen.
  • Page 125 1 2 4 8 switch_a(config)# 802.1p Priority Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). User’s Manual Black Box Harden ed Managed Ethe ure Terminal Mode). on the screen. to enable the egress expe nd to disable the egress expedite...
  • Page 126 Black Box Hardened Managed Ethernet Switch The switch_a(config)# prompt will show on switch_a(config)# Usage: Use wrr-queue cos-map command to spe Command Syntax: wrr-queue cos-map QUEUE_ID C QUEUE_ID Queue ID. Range is 0-3. COS_VALUE CoS values. Up to 8 values (separated by spaces). Range is 0-7.
  • Page 127: Snmp

    DESCRIPTION The description for SNMP. Example: The following example specifies description (description) for SNMP: switch_a(config)#snmp-server description description switch_a(config)# User’s Manual Black Box Hardened Managed Ethernet Switch v1/v2c, SNMP v3 inal Mode). on the screen. nable and no snmp-server enable...
  • Page 128 Black Box Hardened Managed Ethernet Switch Location: Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt w switch_a(config)# Usage: Use snmp-server location command to specify and no snmp-server location command to remove loc Command Syntax:...
  • Page 129 Cold Start Trap: Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). User’s Manual Black Box Hardened Managed Ethernet Switch nity name for SNMP. to remove trap community name for y <1-5> y name 1 (name ) for SNMP:...
  • Page 130 Black Box Hardened Managed Ethernet Switch The switch_a(config)# prompt will show switch_a(config)# Usage: Use snmp-server trap-type enable cold trap for SNMP. Use the no snmp-server trap-type ena cold start trap for SNMP. Command Syntax: (no) snmp-server trap-type enable coldStart Example:...
  • Page 131 SNMP. Use the no snmp-server trap-type enable authenticationFailure command to disable authentication failure trap for SNMP. Command Syntax: User’s Manual Black Box Hardened Managed Ethernet Switch le linkDown command to disable enable linkDown inal Mode). on the screen.
  • Page 132 Black Box Hardened Managed Ethernet Switch (no) snmp-server trap-type enable authenticationFailure Example: The following example enables authentica switch_a(config)#snmp-server tr switch_a(config)# Topology Change Trap: Command Mode: Configure mode Logon to Configure Mode (Configure Term The switch_a(config)# prompt will show switch_a(config)# Usage: Use snmp-server trap-type enable top topology change trap for SNMP.
  • Page 133 Example: The following example adds a user (myuser) using snmp v3 with read-only access mode and without authentication: User’s Manual Black Box Hardened Managed Ethernet Switch unity name ity get name inal Mode). on the screen.
  • Page 134 Black Box Hardened Managed Ethernet Switch switch_a(config)#snmp-server v3-user my switch_a(config)# SNMPv3 Auth-MD5, SNMPv3 Auth-SHA: Command Mode: Configure mo Logon to Configure Mode (Configure Term The switch_a(config)# prompt will show switch_a(config)# Usage: Add a user using snmp v3 with read-only o MD5 or SHA authentication.
  • Page 135 The following example adds a user (myuser) using snmp v3 with read-write access mode, MD5 authentication (mypassword), and encryption pass phrase (mypassphrase): switch_a(config)#snmp-server v3-user myuser rw priv md5 mypassword des mypassphrase switch_a(config)# User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 136 Black Box Hardened Managed Ethernet Switch 802.1x Radius Configuration, Port-Based Authentication Radius Configuration Radius Status: Command Mode: Configure mode Logon to Configure Mode (Config The switch_a(config)# prompt will show switch_a(config)# Usage: Use dot1x system-auth-ctrl command to globally enable authentication. Use no dot1x system-auth-ctrl...
  • Page 137 Command Syntax: radius-server timeout SEC no radius-server timeout SEC <1-1000> The number of seconds for a Switch to wait for a server host to reply before timing out. Enter a value in the range 1 to 1000. Example: The following example specifies 20 seconds for the Switch to wait for a server host to reply before timing out: User’s Manual...
  • Page 138 Black Box Hardened Managed Etherne switch_a(config)#radius-server timeout switch_a(config)# Retransmit: Command Mode: Configure mode Logon to Configure Mode (Configure Termin The switch_a(config)# prompt will show on the screen. switch_a(config)# Usage: Use this command to specify the number radius request to the server before giving up.
  • Page 139 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)# Usage: Use this command to set the interval between reauthorization attempts. User’s Manual Black Box Hardene inal Mode). w on the screen. d Mana ged Ethernet Switch...
  • Page 140 Black Box Hardened Managed Ethernet Switch Use no dot1x timeout re-authperiod command to delete the interval between reauthorization attempts. Command Syntax: dot1x timeout re-authperiod SECS no dot1x timeout re-authperiod SECS <1-4294967295> Specify the seconds between reauthorization attempts. The default time is 3600 seconds.
  • Page 141: Other Protocols

    GROUP set gvrp dynamic-vlan-creation disable bridge GROUP GROUP Bridge-group ID used for bridging. User’s Manual Black Box Hardened Managed Ethernet Switch ure Terminal Mode). on the screen. mand to enable (set) and set gvrp d P globally for the bridge instance.
  • Page 142 Black Box Hardened Managed Ethernet Switch Example: The following example enables dynamic VLAN creation for bridge GROUP (1): switch_a(config)#set gvrp dynamic-vlan switch_a(config)# Per port setting: GVRP: Command Mode: Configure mo Logon to Configure Mode (Configure Term The switch_a(config)# prompt will show on the screen.
  • Page 143 Specify dynamic GVRP multicast registration and deregistration on the port. fixed Specify the multicast groups currently registered on the switch are applied to the port, but any subsequent registrations or deregistrations do applied to the port, but any subsequent registrations or deregistrations do not affect the port.
  • Page 144 Use ip igmp snooping command to enable IGMP Snooping. When this command is given in the Global Config mode, IGMP Snooping is enabled at the switch level. When this command is given at the VLAN interface level, IGMP Snooping is enabled for that VLAN.
  • Page 145 IGMP leave group message is received without sending out a group-specific query. Use the no ip igmp snooping fast-leave command to disable fast-leave processing. User’s Manual Black Box Harden ed Managed Ethernet Switch inal Mode). on the screen. e current IGMP protocol version on o ip igm...
  • Page 146 Black Box Hardened Managed Ethernet Switch Command Syntax: (no) ip igmp snooping fast-leave Example: The following example enables IGMP sno switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping fast-l IGMP querier: Query-interval: Command Mode: Interface mode Logon to Configure Mode (Config Then logon to Interface mode.
  • Page 147 Example: The following example shows interface fe1 (port 1) statically configured to be a multicast router interface on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping mrouter interface fe1 User’s Manual Black Box Hard ened Managed Ethern onse-time command default frequen -time <1-240>...
  • Page 148 The switch_a(config)# prompt will show on the screen. switch_a(config)# Usage: Use ntp enable command to enable NTP for the Switch. Use no ntp enable command to disable NTP for the Switch. Command Syntax: (no) ntp enable Example: The following example enables NTP for the Switch:...
  • Page 149 Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# User’s Manual Black Box Hardened Managed Ethernet Switch ure Terminal Mode). on the screen. s or Domain name of NTP server. ame of NTP s address (192.168.1.100) of NTP...
  • Page 150 Black Box Hardened Managed Etherne Usage: Use this command to to set time zone. Command Syntax: clock timezone TIMEZONE TIMEZONE Specifies the time zo Example: The following example sets time zone (Ca switch_a(config)#clock timezone YST9Y switch_a(config)# Polling Interval: Command Mode: Configure mode...
  • Page 151 The following example sets clock summer-time TIMEZONE (onehour) as daylight saving offset 60 minutes from 4 April AM0:00 to 31 October AM0:00: switch_a(config)#clock summer-time onehour date 4 4 0 0 31 10 0 0 60 switch_a(config)# User’s Manual Black Box Hardened Managed Ethernet Switch...
  • Page 152: Specifications

    Black Box Hardened Managed Ethernet Switch Specifications Applicable Standards Switching Method Forwarding Rate 10Base-T 100Base-TX 100Base-FX 1000Base-T 1000Base-SX/LX Performance Cable 10Base-T 100Base-TX 1000Base-T 100Base-FX 1000Base-SX 1000Base-LX LED Indicators Dimensions Net Weight Power Input Power Consumption Operating Temperature Storage Temperature Humidity Safety IEEE 802.3 10Base-T...
  • Page 153 Environmental Test Compliance NEMA TS1/2 Environmental requirements for traffic control equipment User’s Manual Black Box Hardened Managed Ethernet Switch EN61000-6-2: EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards)
  • Page 154: Appendixa

    Black Box Hardened Managed Ethernet Switch Appendix A B9 DCE pin assignment Pin no. Name RS232 Signal name Data Carrier detect Received data Transmit data Signal ground Data set Ready Clear to send User’s Manual...
  • Page 155: Appendixb

    EUT-1EUTDST EUT-2EUTDST EUT-3EUTDST EUT-4EUTDST EUT-6EUTDST EUT-8EUTDST Russian Federation RFT-2RFTDST RFT-3RFTDST RFT-4RFTDST RFT-5RFTDST User’s Manual Black Box Hardened Managed Ethernet Switch Country and City Lists Europe/Vienna, Europe/Zuri Africa/Tunis , CET, MET, Euro Europe/And orra, Europe/Brus Europe/Pra gue, Europe/Cope Europe/Pari s, Europe/Gibralta...
  • Page 156 Black Box Hardened Managed Ethernet Switch RFT-6RFTDST RFT-7RFTDST RFT-8RFTDST RFT-9RFTDST RFT-10RFTDST RFT-11RFTDST RFT-12RFTDST North America PST8PDT MST7MDT MST7 CST6CDT EST5EDT AST4ADT EST5 AST10ADT YST9YDT NST3:30NDT NAST3NADT NAST9NADT South America & Central America TTST4 SAT3 Asia/Yekaterinburg Asia/Omsk, Asia/Novosi Asia/Hovd, Asia/Kra snoyarsk...
  • Page 157 ACRE5 NORO2 CST4CDT EIST6EIDT Asia MST-8 CST-8 Oceania CST-9:30CDT EST-10EDT LHT-10:30LHDT TST-10TDT NZST-12NZDT CIST-12:45CIDT Africa SAST-2 User’s Manual Black Box Harde ned Man America/Argentin America/Argentina/San_Juan, America/Argentina/Jujuy, America/Argentina/Catamarca, America/Arg entina/Me America/Arg entina/Rio_Gall entina/Ushuaia, America/Arg America/Arg entina/Comod America/Bu enos_Aires, A America/Jujuy, America/Mendoza...
  • Page 158 Black Box Hardened Managed Ethernet Switch EST-2EDT UAEST-4 IST-3IDT JST-2JDT SST-2SDT Universal UCT1 UCT2 UCT3 UCT4 UCT5 UCT6 UCT7 UCT8 UCT9 UCT10 Africa/Mbabane Africa/Cairo, Egypt Asia/Dubai Asia/Baghdad Asia/Amman Asia/Damascus Africa/Ouagadougou, Africa/Abidjan, Africa/Banjul, Africa/Accra, Africa/Conakry Africa/Bissa u, Africa /Monrovia, Africa/Bamako, Africa/Nouakchott,...
  • Page 159 UCT-2 UCT-3 UCT-4 UCT-5 UCT-5:45 UCT-6 UCT-6:30 UCT-7 UCT-8 UCT-9 UCT-9:30 UCT-10 User’s Manual Black Box Harde ned Ma Pacific/Honolulu, Etc/GMT+10, HST, US/Hawaii, SystemV/HST10 Pacific/Niue, Pacific/Pa Pacific/Apia, Pacific/Midway, Etc/GMT+11 Pacific/Samoa, US/Samoa Africa/Algiers, Africa/Luanda, Africa/Porto-Novo, Africa/Douala, Africa/Bangui, Africa/Ndjamena, Africa/Kinsh asa, Africa/Br...
  • Page 160 Black Box Hardened Managed Ethernet Switch UCT-11 UCT-11:30 UCT-12 UCT-13 UCT-3:30 UCT-4:30 IST-2IDT CST6MEX CST6 EET-2EETDST2 EET-2EETDST3 EET-2EETDST2W2K UCT-14 UCT9:30 UCT12 North America (Canada) PST8PDT_CA MST7MDT_CA CST6CDT_CA EST5EDT_CA AST4ADT_CA North America (Cuba) EST5EDT_CU Pacific/Saip an, Pacific/Truk, Pacific/Noumea, Pacific/Port_Moresby, Etc/GMT-10 , Pacific/Yap...
  • Page 161 North America (Mexico) PST8PDT_MX MST7MDT_MX CST6CDT_MX North America (Turks and Caicos) EST5EDT_TC Additions Since 10g RTM EST5EDT_INDIANA UCT-8_WA User’s Manual Black Box Hardened Managed Ethernet Switch America/Nassau, America/Santo_Domingo, America/Port-au-Prince, America/Bogota America/Tijuana, America/Ensenada, Mexico/BajaNorte America/Chihuahua, America/Hermosillo, America/Mazatlan, Mexico/BajaSur America/Guatemala America/Grand_Turk America/Indiana/Indianapolis,...