INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000, ROBUST 3000
2. SPECIFICATIONS AND COMPONENTS
2.1 TECHNICAL SPECIFICATIONS
Purified water flow rate
Feed water flow rate, L/h
Concentrate flow rate, L/h
Inlet water pressure, bar (psi)
Operating pressure, bar (psi)
Feed water temperature, °С (°F)
Ambient air temperature, °С (°F)
Connection to water mains
Overall dimensions, H × W × D, mm
Weight, kg (lb), max.
Electrical rating
Power consumption, W (hp), max.
Ingress protection rating
At feed water TDS of 1000 mg/L (ppm) and temperature of feed water of 25 °С (77 °F), ±10%.
1
If the pressure of water in your system does not meet the requirement, install a pressure booster pump to raise
2
it. If water pressure exceeds the upper limit, install a pressure regulator before the RObust .
Using the RObust with feed water temperature between 20 °С (68 °F) and 30 °С (86 °F) produces a lower rejec-
3
tion rate and higher flow rate, which yields higher TDS of purified water. Using the system with feed water above
30 °С (86 °F) is advised against.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2016
Parameter
, L/h
1
gpm
gpm
gpm
inсh
Value
RObust 1000
55–60
0.24–0.26
110–130
0.48–0.57
55–65
0.24–0.26
2.0–5.0
(29–72.5)
2
5.0–7.0 (72.5–101.5)
4...30
(39...86)
3
5...40
(41...104)
3
JG ¼
420 x 220 x 425
16.5 x 8.7 x 16.7
6 (13)
230 V, 50 Hz
110 V, 60 Hz (USA)
80 (0.11)
IP 54
RObust 3000
145–150
0.64–0.66
290–310
1.28–1.37
145–150
0.64–0.66
JG ⅜
445 x 480 x 380
17.5 x 18.9 x 15.0
25 (55)
250 (0.34)
33