Ecosoft ROBUST 1000 Installer And User Manual page 4

Reverse osmosis systems
Hide thumbs Also See for ROBUST 1000:
Table of Contents

Advertisement

INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000, ROBUST 3000
ROBUST 1000
Inlet
pressure
gauge
Low-pressure
switch
Water inlet
connection
Sediment
pre-filter
Carbon
pre-filter
Technological scheme of RObust 1000 is shown in Figure 2. After the pre-filters, the pressure
booster pump feeds the water to the reverse osmosis membrane array with two membrane
modules. Permeate from both modules goes to the permeate collector, and concentrate from the
1
and 2
modules goes to the 3
st
nd
the concentrate is discarded to drain via concentrate flow restrictor and drain port in port rack.
Pressure gauge no. 2 shows pressure between the 2
purified water line or pressure tank (if installed), passing through the carbon post-filter. Purified
water line may go to purified water faucet or be connected with some other consumer appliance.
High-pressure switch installed before the post-filter reads pressure in permeate line and starts the
reverse osmosis system when it drops (due to taking of some water from the pressure tank or
opening purified water faucet). When the system switches on, entry solenoid valve is opened and
booster pump is powered up, which allows to feed water into the system. When purified water
stops being drawn from the system, pressure starts to build up and closes high-pressure switch
switching off the system.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2016
Membrane
module
Inlet
Operating
solenoid
Booster
pressure
valve
pump
gauge
one. Second stage permeate goes to the permeate collector, and
rd
Drain
outlet
Figure 2
and 3
membranes. Permeate goes to the
nd
rd
Flow
restrictor
High-pressure
switch
Tank
Carbon
connection
post-filter
31
Permeate
outlet

Advertisement

Table of Contents
loading

This manual is also suitable for:

Robust 3000

Table of Contents