Prerequisites For Hot-Plugging Pci Adapters In A Linux Partition - IBM 7311-D11 Removal And Replacement Procedures

Table of Contents

Advertisement

Figure 36. PCI adapter EMC shield in the closed position
17. Run the lsslot command to verify that the slot is occupied.
For example, Enter lsslot -c pci -s U7879.001.DQD014E-P1-C3
The following is an example of the information displayed by this command:
# Slot
Description
64 bit, 133MHz slot 0001:40:01.0

Prerequisites for hot-plugging PCI adapters in a Linux partition

When you install, remove, or replace a PCI adapter in a Linux partition that is powered on, you might
need to complete some prerequisite tasks.
The Linux system administrator needs to take the PCI adapter offline prior to removing, replacing, or
installing a PCI adapter with the system power on (hot-plugging). Before taking an adapter offline, the
devices attached to the adapter must be taken offline as well. This action prevents a service representative
or user from causing an unexpected outage for system users.
Before hot-plugging adapters for storage devices, ensure file systems on those devices are unmounted.
After hot-plugging adapters for storage devices, ensure the file systems on those devices are remounted.
Before hot-plugging an adapter, ensure that the server or partition is at the correct level of the Linux
operating system (Linux operating system 2.6 or later).
Device(s) U7879.001.DQD014E-P1-C3 PCI-X capable,
5790 and 7311 model D11 removal and replacement procedures
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

5790