TOP-LEVEL MENU

The sensor is configured with the three buttons on the sensor face (UP, DOWN and
SELECT) and the sensor's LCD. To access the sensor's Top-level menu, simply hold
down the SELECT button for five seconds. The display menu will automatically begin
to scroll through the TOP-LEVEL MENU.
When the menu scrolls to an item you wish to configure, simply press the SELECT
button to choose that item. The TOP-LEVEL MENU will continue to scroll through the
following (UNITS – TANK – SAFE – VALUES – RUN), so if you miss your selection,
it will appear again shortly.
To return to the TOP-LEVEL MENU, press SELECT when EXIT appears.
To return to Operational Mode of the sensor, press SELECT when RUN appears in the TOP-LEVEL
MENU.
Note: To speed up the scrolling of the values on the display, hold down the SELECT button while
holding down the UP or DOWN buttons.

SET UNITS

®
The EchoSafe
displays information in the following units:
inches, feet, centimeters, meters or percentage. The value
shown on the display represents the amount of liquid in the
tank.
1) In TOP-LEVEL MENU mode, select UNITS.
2) Select INCHES, FEET, CM, METERS or PERCENT.
SAVED will display.
3) Select EXIT to return to the TOP-LEVEL MENU.
MEASURING SENSOR HEIGHT AND FILL-HEIGHT
HEIGHT – Distance from the transducer face to the bottom of the
tank.
FILL-H – Maximum fill height of the liquid from the bottom of the
tank.
Note: The Height and Fill Height settings also determine the 4 to 20 mA
current span. The Height setting determines the 4mA position and the
Fill-H setting determines the 20 mA position.
|