IBC control Variotron VVX MiniMax V Manual

IBC control Variotron VVX MiniMax V Manual

Control unit for rotating heat exchanger

Advertisement

MANUAL
CONTROL UNIT
FOR ROTATING
HEAT EXCHANGER
MiniMax
V / VK
Revised 2014-10-07
Version 1.3.1
F21037901GB

Advertisement

Table of Contents
loading

Summary of Contents for IBC control Variotron VVX MiniMax V

  • Page 1 MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MiniMax V / VK Revised 2014-10-07 Version 1.3.1 F21037901GB...
  • Page 2 To meet the requirements of the EMC regulations a shielded cable must be used for both motor and control signal. The screen must be connected in both ends. ___________________________________________________________________________ IBC control Brännerigatan 5 A  SE-263 37 Höganäs  Tel. +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 3: Table Of Contents

    Checks before power on Starting procedure Operational indications Alarm indications Protective and operational functions Fault finding ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 4: Minimax

    Output frequency 1- 20 Hz 10 A Min. frequency Input fuse max. Max. frequency 40-100 Hz ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 5: Control Connections

    The motor rotates with adjusted maximum speed. Button high speed The motor rotates with adjusted minimum speed. Button low speed ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 6: Adjustments

    0-20 mA 4-20 mA Cleaning function off Cleaning function on Rotation monitor off Rotation monitor on ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 7: Checks Before Power On

    Let the central control run the rotor at max- and min speed and check that the speed of the rotor is correct. ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 8: Operational Indications

    Restart Disconnection Disconnection between inverter and motor is not allowed when motor is under load. ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 9: Fault Finding

    Under 50 Hz the voltage is less than 230 V between the phases. ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 10: ___________________________________________________________________________

    ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 11: ___________________________________________________________________________

    ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  Fax +46 42 33 03 75...
  • Page 12: ___________________________________________________________________________

    Brännerigatan 5 A • SE-263 37 Höganäs Tel. +46 42 33 00 10 • Fax +46 42 33 03 75 ___________________________________________________________________________ IBC control  Brännerigatan 5 A  SE-263 37 Höganäs  Tel +46 42 33 00 10  FAX +46 42 33 03 75...